6.4.3 Connecting the GA 5000EACEC Spray Gun
1.0 AT
I
0
Main Switch
Hauptschalter
Prim. Fuse
Sicherung
Mains power IN
Netz Eingang
Air input
6 - 8bar
87-116 psi
Clean and dry air
Saubere und trockene Luft
6.5.2 (ISO 8573-1:2010)
Air input
Lufteingang
Control air
Steuerluft
Fan air
Formluft
Atomizing air
Zerstäuberluft
Spraygun
Sprühpistole
Interface
Schnittstelle
IN CAN Bus OUT
Data and Interlock
Daten und Verriegelung
CAN
Address
Service
Port
Restrictor for air during cleaning
Drossel für Luft während dem Spülen
Imax. = 1.0A
Umax. = 20Vpp
0102
II (2) G
SIRA 16 ATEX 5290X
Typ / Type:
EPG 5000
115VAC - 230VAC
50Hz / 60Hz
2359451
max. 40W
Wagner International AG
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Serie Nr.:
Serial No.:
Spannung:
Voltage:
Artikel Nr.:
Article No.:
Eingangsleistung:
Input Power:
Schutzart:
IP Code:
Norm:
Standard:
EN 50176:2009
IP 40
Eingangsstrom:
Input Current:
max. 0.5A
EN 50050-1:2013
Baujahr:
Year of manufacture:
0
1
2
34
5 67
8
9
0
1
2
34
5 67
8
9
B_05727
8
9
GA 5000
EPG 5000
7
1
2
3
4
5
6
1
For the product supply
6
For the compressed air supply
2
Shaping air hose
7
Control cable
3
Atomizing air hose
8
Grounding cable
4
Control air hose
9
Mains cable
5
Gun cable
1. Place the control unit outside the explosion zone.
2. Mount spray gun to a grounded gun support.
3. Connect the grounding cable to the control unit and the signal ground.
4. Connect the gun connection cable to the control unit.
5. Connect the control unit to the higher-level controller (if available).
6. Connect the air hoses to the control unit and the spray gun in accordance with the
figure.
7. Set all airs to "0" using the regulator on the front side of the control unit!
8. Connect the control unit to the compressed air supply.
9. Connect the spray gun to the product supply system.
10. Connect the control unit to the power supply.
6.4.4 Ventilation of the Spray Booth
The electrostatic spraying equipment may only be operated in defined spraying areas and in
accordance with the EN 16985:2018 standard or under comparable ventilation conditions.
The electrostatic spraying equipment must be locked to the technical ventilation so that the
coating product supply and the high voltage are not effective as long as the technical
ventilation is not operated with the minimum exhaust air volume flow or a larger exhaust air
volume flow.
Ensure that the excess coating product (overspray) will be collected up safely.