Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
6 Assembly and Commissioning
34
Order number 2360922 | Edition 09/2022
WARNING
Toxic and/or flammable vapor mixtures!
Risk of poisoning and burns.
4
Operate the device in a spray booth approved for the working materials.
Or:
4
Operate the unit on an appropriate spraying wall with the ventilation (extraction)
switched on.
4
Observe national and local regulations for the outgoing air speed.
6.4.5 Air Supply Lines
WARNING
Hose connections!
Risk of injury and damage to the device.
4
Do not mix up hose connections of product hose and air hose.
4
Ensure that only dry, clean atomizing air is used in the spray gun! Dirt and moisture in
the atomizing air worsens the spraying quality and spray pattern.
6.4.6 Product Supply Lines
NOTICE
Impurities in the spraying system
Spray gun blockage, products harden in the spraying system.
4
Flush the spray gun and paint supply with a suitable flushing agent before
commissioning.
DANGER
Bursting hose, bursting threaded joints!
Danger to life from injection of product.
4
Ensure that the hose material is chemically resistant to the sprayed products.
4
Ensure that the spray gun, fittings and product hose between the device and the
spray gun are suitable for the pressure generated in the device.
4
Ensure that the following information can be seen on the high-pressure hose:
4
Manufacturer
4
Permissible operating pressure
4
Date of manufacture
6.4.7 Grounding
During normal operation, perfect grounding of all conductive parts such as floors, walls,
roofs, barriers, work pieces, transport devices, coating product tank, coating product supply
or construction parts in the spray area, with exception of the high-voltage parts, is important
for work safety and optimum coating.
Parts of the booth must be grounded in accordance with EN 16985:2018.