33
VERSION 05/2018
ORDER NUMBER DOC 2312956
GA 4000ACIC
6.4.4 PRODUCT SUPPLY LINES
NOTICE
Impurities in the spraying system!
Spray gun blockage, products harden in the spraying system.
Flush the spray gun and paint supply with a suitable flushing agent.
6.5
GROUNDING
A conductive connection (potential equalization cable) must be established between
original tank and the equipment.
Ground all device components.
Ground the work pieces to be coated.
6.6
SAFETY CHECKS
Carry out safety checks in accordance with Chapter
.
6.7
LACQUER PREPARATIONS
The viscosity of the lacquer is of great importance. The best spraying results are obtained
with values between 80 and 260 millipascal x Sec (mPas).
Processing of up to 260 mPas is generally possible without problems if high coating
thicknesses are required. It is important for the optimum coating quality that the paint
temperature is kept constant during coating.
Please also read the technical data sheet of the lacquer for optimal processing, viscosity
adjustment and intermixing of the product.
In the case of application problems contact the lacquer manufacturer.