18
VERSION 05/2018
ORDER NUMBER DOC 2312956
GA 4000ACIC
4.2.6 TOUCHING HOT SURFACES
Hazard due to hot surfaces because of hot coating products!
Risk of burn injuries.
Only touch hot surfaces if you are wearing protective gloves.
When operating the device with a coating product with a temperature of > 43 °C;
109 °F:
– Identify the device with a warning label "Warning – hot surface".
Order No.
9998910 Instruction label
9998911 protection label
Note:
Order the two stickers together.
4.2.7 MAINTENANCE AND REPAIR
Hazard due to improper maintenance and repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Do not change or modify the device; if change is necessary, contact WAGNER.
Only repair and replace parts that are listed in Chapter
and Chapter
that are
assigned to the unit.
Do not use any defective components.
Exclusively use accessories listed in Chapter
and that are assigned to the unit.
Before all work on the device and in the event of work interruptions:
– Switch off the energy and compressed air supply.
– Relieve the pressure from the spray gun and device.
– Secure the spray gun against actuation.
Observe the operating and service manual for all work.
4.2.8 PROTECTIVE AND MONITORING EQUIPMENT
Hazard due to removal of protective and monitoring equipment!
Danger to life and equipment damage.
Protective and monitoring equipment must not be removed, modified or rendered
unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment, the system must
not be operated until these defects are remedied.