24
03/2015
GB
20. Correction of Malfunctions
Problem
Cause
Remedy
No coating material
emerges from the
nozzle
•
Nozzle clogged
•
Material volume setting
turned too far to the right (-)
•
No pressure build-up in
container
•
Container empty
•
Feed tube loose
•
Feed tube clogged
➞
Clean
➞
Turn to the left (+)
➞
Tighten container
➞
Refill
➞
Insert
➞
Clean
Coating material
drips from the
nozzle
•
Coating material assembly
at air cap, nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
➞
Clean
➞
Union nut tighten
➞
Change
➞
Change
Atomisation too
coarse
•
Material volume too large
Material volume setting
turned too far to the left (+)
•
Nozzle contaminated
•
Viscosity of coating material
too high
•
Too little pressure build-up
in container
•
Air filter heavily soiled
➞
Turn material volume
setting to the right (-)
➞
Clean
➞
Dilute further
or
set Stage "2"
➞
Tighten container
➞
Change
Spray jet pulsates
•
Coating material in
container running out
•
Nozzle seal worn
•
Air filter heavily soiled
➞
Refill
➞
Replace
➞
Change
Coating material
causes "paint tears"
•
Too much coating material
applied
•
Viscosity of coating material
too low
➞
Turn material volume
setting to the right (-)
Too much fog of
coating material
(Overspray)
•
Distance to the object too
large
•
Too much coating material
applied
•
Material very thin
➞
Reduce distance
➞
Turn material volume
setting to the right (-)
➞
dilute less
or
set Stage "1"
Содержание FOLIATEC Spray system
Страница 1: ...Spr hsytem Spray system Syst me de pulv risation Spuitsysteem D GB F NL...
Страница 2: ...03 2015 3 a b 1 1 2 10 3 6 8 5 4 13 12 11 7 9 2 B A...
Страница 3: ...03 2015 b 5 a 7 5 25 cm 4 1 2 6 8 9 7 8 6 7 4 3 2 1...
Страница 4: ...03 2015 54 1 13 D 14 26 GB 27 39 F 40 52 NL 11 a b 4 3 5 10 6...