22
03/2015
GB
•
When coating material builds up on the nozzle and air cap, clean both parts with a
solvent or water.
14. Interruption of Work till 4 Hours
•
Turn the machine off.
•
Insert the spray gun into the gun holder.
•
When processing 2-component varnishes, clean the device immediately.
15. Taking Out of Operation and Cleaning
Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
1) Turn the machine off. Vent the container in case of longer breaks and after the work
has been terminated. This can be done by briefly turning open and then closing the
container or by pulling the trigger guard and letting the paint into the original paint
container.
2) Unscrew the container. Empty any remaining coating material back into the material tin.
3) Preclean the container and feed tube with a brush. Clean the ventilating bore (Fig. 8).
4) Pour solvent or water into the container. Screw the container back on.
5) Turn on the machine.
6) When rinsing the gun with solvents, keep a distance of at least 5 m
from
the
device.
Spray the solvent or water into a container or a cloth.
7) Repeat the above procedure until the solvent or water emerging from the nozzle is clear.
8) Turn off the machine.
9) Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION!
Never clean seals and nozzle or air holes of the spray gun with metal
objects.
10) Unscrew the union nut (Fig. 9, 1) and remove the air cap (2) and nozzle (3). Clean the
air cap, nozzle seal (4) and nozzle with a brush and solvent or water.
11) Clean the outside of the spray gun and container with a cloth soaked in solvent or water.
12) Assemble the parts again (see “Assembly”).
Assembly
1) Push the nozzle seal (fig. 10, 4) over the needle (5); the groove (slot) should point
towards you.
2) Put the nozzle (fig. 10, 3) onto the gun body (6) and find the correct position by turning
it.
3) Put the air cap (fig. 9, 2) onto the nozzle (3) and tighten it using the union nut (1).
4) Place the container seal (fig. 9, 7) from below on the suction tube (8) and slide it over
the collar, while turning the container seal slightly.
5) Insert the suction tube with container seal in the gun body.
Содержание FOLIATEC Spray system
Страница 1: ...Spr hsytem Spray system Syst me de pulv risation Spuitsysteem D GB F NL...
Страница 2: ...03 2015 3 a b 1 1 2 10 3 6 8 5 4 13 12 11 7 9 2 B A...
Страница 3: ...03 2015 b 5 a 7 5 25 cm 4 1 2 6 8 9 7 8 6 7 4 3 2 1...