47
B_04243
A
5
X
1
5
B_05072
OPERATING MANUAL
VERSION 07/2014
ORDER NUMBER DOC2349980
Vent
Procedure:
1
Turn the pump upside down. Remove threaded plug (5).
2
Slowly start up (vent) the pump until no air bubbles appear from the oil suction fi tting.
3
Oil level A in the oil tank has to be within the specifi ed markings (X).
4
Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
5
Mount piston cover (1) and hood with casing.
6
The device is ready for operation again.