10. Servicing
10.1 General servicing
Servicing of the unit should be carried out once annually by the
WAGNER service.
1. Check high-pressure hoses, device connecting line and plug
for damage.
2. Check the inlet valve, outlet valve and filter for wear.
10.2 High-pressure hose
Inspect the high-pressure hose visually for any notches or bulges, in
particular at the transition in the fittings. It must be possible to turn
the union nuts freely.
i
The risk of damage rises with the age of the high-
pressure hose. Wagner recommends replacing high-
pressure hoses after 6 years.
11. Repairs at the unit
Switch the unit OFF.
Before all repair work: Unplug the power plug from
the outlet.
11.1 Relief valve
1. Use a drift punch of 2 mm to remove the grooved pin (Fig. 13,
Item 1) from the relief valve handle (2).
2. Remove the relief valve handle (2) and cam base (3).
3. Using a wrench, remove the valve housing (4).
4. Ensure that the seal (5) is seated correctly, then screw the new
valve housing (4) completely into the filter block (6). Tighten
securely with a wrench.
5. Align the cam base (3) with the hole in the filter block (6).
Lubricate the cam base with grease and slide on the cam base.
6. Bring the hole in the valve shaft (7) and in the relief valve
handle (2) into alignment.
7. Insert the grooved pin (1) to secure the relief valve handle in
position.
5
3
7
6
4
2
1
11.2 Inlet and outlet valve
1. Remove the four screws in the front cover and then remove
the front cover.
2. Switch the unit ON and then OFF so that the piston rod is
positioned in the lower stroke position
Danger of crushing - do not reach with the fingers or
tool between the moving parts.
3. Unplug the power plug from the outlet.
4. Pull off clamp on suction tube and remove return hose.
5. Unscrew the connection hose (Fig. 14, item 1) from the high-
pressure filter.
6. Swivel the unit 90° to the rear in order to work more easily on
the material feed pump.
7. Loosen and remove the inlet valve housing (2) from the upper
housing.
8. Remove bearing ring (3), O-ring (4), O-ring (5), inlet valve seat
(6), inlet valve ball (7) and upper ball guide (8).
9. Clean all the parts with the corresponding cleaning agent.
Check the inlet valve housing (2), inlet valve seat (6) and inlet
valve ball (7) for wear and replace the parts if necessary. If the
worn inlet valve seat (6) is unused on one side, install it the
other way around.
1
8
6
7
5
4
3
2
10. Screw out outlet valve housing (Fig 15, item 9) from the piston
(10) with 3/8 inch hexagon socket head wrench.
11. Remove the upper seal (11), upper ball guide (12), outlet valve
ball (13), washer (14) and outlet valve seating (15).
12. Clean all the parts with the corresponding cleaning agent.
Check outlet valve housing (9), outlet valve seat (15), outlet
valve ball (13) and upper ball guide (12) for wear and replace
parts if necessary. If the worn outlet valve seat (15) is unused
on one side, install it the other way around.
13. Carry out installation in the reverse order.
14. If you plan to replace the fluid section packings, move on to
section 11.3. If not, reassemble fluid section in the reverse
order of how it was disassembled.