26
Basic 8000
.
OPERATING MANUAL
VERSION 12/2010
ORDER NUMBER DOC 3305595
8
ELIMINATION OF FAULTS
Malfunction
Cause
Remedy
Suction performance is too weak
(safety stop triggers)
●
Fuses defective.
●
The fi lter cleaning system is not
activated.
●
The solenoid valves in the
fi ltering system are defective.
●
The cleaning fi lters are clogged.
●
Replace the fuses.
●
Start and shorten the cleaning
intervals if required (interval
program in the control cabinet).
●
Replace the solenoid valves.
●
Clean or if required replace the
fi lter cartridge.
Dust is exhausted from the
blower
●
The fi lter cartridges are loose or
incorrectly
installed.
●
The seal of the fi lter cartridge is
defective.
●
The fi lter cartridges are
damaged.
●
Install the fi lter cartridges
correctly.
●
Replace the foam rubber gasket.
●
Replace the fi lter cartridges.
Excessive noise and/or vibrations
from the housing
●
The ventilator bearings are
defective.
●
Dust deposits on the ventilator
blades.
●
Replace the electric motor.
●
Clean the ventilator blades.
No powder feed
●
The injector is clogged or worn.
●
The powder hose is dirty or
bent.
●
The spray guns are clogged.
●
Insuffi cient feed or dosage air.
●
Clean the injector and if required
replace worn parts.
●
Clean the powder hose and
check the hose for bends.
●
Clean the spray guns.
●
Check the air supply system.
Содержание Basic 8000
Страница 1: ...Spray wall Basic 8000 Version 12 2010 Translation of the original Operating manual ...
Страница 2: ......
Страница 35: ......