14
Basic 8000
.
OPERATING MANUAL
VERSION 12/2010
ORDER NUMBER DOC 3305595
5
ASSEMBLING
SIHI_05007_ENG
WARNING
Incorrect assembly/ installation!
Risk of injury and damage to the equipment.
Installation may only be performed by trained and authorized
persons. We recommend that installation work is carried out by
WAGNER personnel.
The Basic 8000 spray wall is delivered disassembled to the site of installation.
Final assembly is performed on-site.
5.1
REQUIREMENTS FOR THE INSTALLATION SITE
Temperature range
0-40°C; 32-104°F
Max. air humidity
75%
Electrical connection
220-380 V/50 Hz
System ground (band or rod grounding)
according to VDE 0141 low impedance
with NYAF > 16 mm²
Compressed air connection
0.6-0.8 MPa; 6-8 bar; 97-116 psi
Compressed air quality
according to ISO 8573.1
Quality class 3.5.2
CAUTION
For safe operations, the system requires a high compressed air quality!
Any damage to the system that can be attributed to insuffi cient air quality must be
rectifi ed at the owner‘s expense.
Wagner offers the appropriate maintenance unit. Ask Wagner service for advice.