Start
up
6
0241886
– HiCoat-ED Pump
08/2008
2. Start
up
2.1
Preparing the HiCoat-ED Pump
Caution
The HiCoat-ED Pump
must
be grounded to prevent static charging!
In this case, you must use the Wagner Special hose!
2.1.1 Connecting the powder hose
Push the powder hose
2
onto the collector-nozzle
1
until it is firmly fixed.
Here, you should use the
Special hose
with an inner diameter of 8, 9 or 10 mm, as
illustrated in chapter
5.4
"
Special accessories
". This hose is equipped with an integrated
grounding wire, which contributes greatly to preventing powder charging.
1
2
PI_01
Conductive
collector-nozzle
Powder hose with
grounding wire
Conductive nut
2.1.2 Grounding
The HiCoat-ED Pump
must
be fitted with a grounding cable in application modes.
The grounding cable
must
be connected
to the rear side of the control unit or to
the system ground:
M5 threaded hole with 4 mm core hole
diameter for grounding cable
See chapter
5.4
"
Special accessories
"
for article numbers.
Use only conductive O-ring.
LA_02