Maintenance and rectification of malfunctions
12
0241886
– HiCoat-ED Pump
08/2008
3.2
Checking the collector-nozzle for wear
Penetration depths:
Hint
Green:
the collector-nozzle does not have to be exchanged
Red:
the
collector-nozzle
must
be exchanged
The O-rings are located according to the specific quality demands.
good
worn
Collector-nozzle 0241229
Testing gauge 0241929
•
Push the testing gauge into the
collector-nozzle right
up to the limit
stop
.
•
This collector-nozzle is
not
worn
(new collector-nozzle).
•
This collector-nozzle is worn and
must
be exchanged.
•
Push the cleaned or new collector-
nozzle into the housing right
up to
the limit stop
.
•
Push the outer nut over the
collector-nozzle
and tighten it
securely
again.