Maintenance and rectification of malfunctions
08/2008
0241886
– HiCoat-ED Pump
13
3.3 Disposal
04_Entsorgung.doc
Only for EU countries
Do not dispose of electric tools together with household waste
material!
In observance of the European Directive 2002/96/EC on waste electrical
and electronic equipment and implementation in accordance with
national law, this product is not to be disposed of together with household
waste material but must be recycled in an environmentally friendly way!
Wagner or one of our dealers will take back your used Wagner waste electrical or electronic
equipment and will dispose of it for you in an environmentally friendly way. Please ask your
local Wagner service center or dealer for details or contact us direct.
4.
Rectification of malfunctions
Malfunction Cause
Remedy
Insufficient powder
delivery
- Collector-nozzle
clogged
- Collector-nozzle
worn
- Leak between container and
HiCoat-ED Pump
- Replace and clean collector-
nozzle
- Replace collector-nozzle
- Replace O-ring
Pulsed powder delivery
- Insufficient overall air
- Collector-nozzle
not mounted
correctly
- Increase overall air quantity
- Clean thread of the outer nut
and tighten nut securely