12
EN-RATIOfresh-250-400_TI-MA-0809-11214900
Figure 9 Controller connection
3
Socket flat data cable;
4/5
Mains (plug/socket);
6/7
Circulation pump (plug/socket);
8/9
Primary circuit sensor (plug/socket);
10/11
Meter (plug/
socket);
12/13
Data cable (plug/socket);
14/15
External switching output for heating circuit control (plug/socket);
16
Micro-fuse, 250V/T6,3 A;
17
Micro-fuse, 250V/T400 mA;
18/19
Secondary sensor hot/cold water (plug/socket);
20/21
Primary pump (plug/socket).
12
13
11
1
2
3
4
PE
L
N
P1
PE
L
N
P2
PE
L
N
Low voltage area
230 V
+5V
+15V
+
RT
+
10
9
11
3
13
9
19
15
5
21
7
16
17
14
18
8
10
12
6
20
4
at rest
11
12
13
activated
11
12
13
Hot-/cold water sensors
Hot water sensor (blue)
Mass (brown)
Circulation / cold water
sensor (blue)
Primary circuit sensors
Buffer cyl. sensor (blue)
Mass (brown)
Primary flow sensor (blue)
Optional data cable
Plus 5V (yellow)
TxData (white)
RxData (green)
Mass (brown)
Optional circulation pump
Grounding (yellow/green)
Zero (blue)
Phase (black or brown)
Primary pump cable
Grounding (yellow/green)
Zero (blue)
Phase (black or brown)
Mains connection
Grounding (yellow/green)
Zero (blue)
Phase (black or brown)
Single jet meter
Mass (brown
Impulse (green)
not used
not used
22
Содержание RATIOfresh 250
Страница 25: ...EN RATIOfresh 250 400_TI MA 0809 11214900 25 ...
Страница 26: ...26 EN RATIOfresh 250 400_TI MA 0809 11214900 ...