manualshive.com logo in svg
background image

Lithium Cube™ EX5 by Wagan Tech

®

www.wagan.com

10

8. TROUBLESHOOTING

Indicator/Content

Problem

Solution

Icons are not 

displayed.

         +

AC input wattage can’t be dis-

played, and AC charging fails.

AC Input Failure

Check the AC charging cable for a 

good connection at both the wall outlet 

and the charging input port of the unit.

 Icon is not displayed.

         +

Battery level indicator does not 

scroll.

         +

The product cannot be charged 

by either the solar panel or the 

car input.

DC Input Failure

Check and make sure the DC input is 

connected with the correct polarity.
Check whether the solar panel or car 

lighter port works properly.

High Temperature 

Charge Protection

Let the unit cool down for 2hrs before 

recharge.

Battery Failure

Contact Wagan Support Team

No response after pressing the 

main power button.

System Halted

After discharging the power station until 

the battery is drained, recharge the 

product and restart it.

Battery Failure

Contact Wagan Support Team

Icon flashes.

         +

Icon stays on.

Battery Failure

Please restart after removing the AC 

Input & Solar Input. If the error hasn’t 

been fixed, please contact Wagan sup-

port team.

Icon flashes.

         +

Icon stays on.

Inverter Failure

Please restart after removing the AC 

Input & Solar Input. If the error hasn’t 

been fixed, please contact Wagan sup-

port team.

AC output power can’t be 

displayed.

AC Output 

Failure

Contact Wagan Support Team

Icon flash together.

         +

Icon stays on.

         +

The AC output port cannot power 

the devices normally.

AC Output  

Overload  

Protection

Normal operation will be resumed 

automatically after you remove the 

overloaded devices and restart the unit. 

Electrical devices should be used within 

rated wattage.

Icon flash together.

         +

Icon stays on.

         +

The AC/DC output port cannot 

power the devices normally.

Over 

Temperature 

Protection

Please confirm whether the fan inlet and 

outlet are blocked, if not, normal opera-

tion will be resumed automatically after 

the temperature of unit drops.

Содержание LITHIUM CUBE EX5

Страница 1: ...Item No 8835 User s Manual...

Страница 2: ...ly reduced or the product may cease to work WARNINGS identify important safety concerns when operating this equipment Failure to follow these warnings could result in personal injury or loss of life 1...

Страница 3: ...tely and stop using the product place it in an open area keep it away from combustible materials and people and dispose of it in accordance with local laws and regulations Do not move the product duri...

Страница 4: ...Power Button USB C Output Port AC Power Button AC Output Sockets Main Power Button AC Charging Input Port Anderson Input Port Stackable Flat Top Design 12V DC Output DC Power Button USB A Output Ports...

Страница 5: ...e AC Charging input port on the side of the Lithium Cube then plug the other end of the cable into an AC Wall outlet that supports a current of 10A or greater Wagan is not responsible for any damage c...

Страница 6: ...anels via the Anderson port The Lithium Cube comes with a built in 10A MPPT solar controller capable of charging up to 150W Do not use solar panels with their own built in solar controller Wagan is no...

Страница 7: ...ct the AC appliance or appliances to any AC Outlet 2 Turn the power inverter ON by pressing the AC power button 3 Turn on one AC appliance and observe the power indicator 4 After appliance use turn OF...

Страница 8: ...oon as convenient 6 OPERATING TIMES Below are typical products that can be operated by the Lithium Cube with estimated operating times The operating times will vary depending on the internal battery c...

Страница 9: ...esults may vary based on model brand used Assumes continuous operation 7 USER MAINTENANCE Please use or store the product in an environment with a temperature between 68 F to 86 F away from water inte...

Страница 10: ...is drained recharge the product and restart it Battery Failure Contact Wagan Support Team Icon flashes Icon stays on Battery Failure Please restart after removing the AC Input Solar Input If the error...

Страница 11: ...use electrical devices that exceed the rated power of unit Unable to power on during charging Charging over heat Protection Remove the unit from a high temperature environment Give it 2hrs to cool do...

Страница 12: ...RECYCLING DISPOSAL If conditions permit make sure that the battery is fully discharged before disposing of it in a designated battery recycling bin The product contains batteries with potentially har...

Страница 13: ...lbs 7 2 kg Protection Over Voltage Protection Overload Protection Over Temperature Protection Short Circuit Protection Low Tempera ture Protection Low Voltage Protection Overcurrent Protection Over Ch...

Страница 14: ...be EX5 by Wagan Tech www wagan com 14 Environmental Operating Temperature Optimal Operation Temperature 68 F 86 F Storage Temperature 4 F 113 F Charging Temperature 32 F 113 F DIscharging Temperature...

Страница 15: ...s expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of perfor...

Страница 16: ...gan com US CAN Toll Free 1 800 231 5806 Telephone 1 510 471 9221 31088 San Clemente Street Hayward CA 94544 U S A 2023 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks of...

Отзывы: