Indicator/Content
Problem
Solution
AC Input Grid
Frequency
Abnormal
Disconnect the unit from the grid and
turn it off.
Then reconnect to the grid and restart it.
The indicator “E5” will display for 3
seconds before learning the current
electrical frequency.
If the indicator “E5” remains on after
5 seconds, please check the electrical
frequency.
Inverter Output
Voltage
Abnormal
Contact Wagan Support Team.
Inverter Failure
Contact Wagan Support Team.
Solar Input Over
Voltage
Please use solar panel(s) with a voltage
of 11V−25V DC.
Solar Input Over
Current
Please use solar panel(s) within the input
wattage of 150W.
9. RECYCLING/DISPOSAL
If conditions permit, make sure that the battery is fully discharged before disposing of it in
a designated battery recycling bin. The product contains batteries with potentially harmful
chemicals, it is strictly prohibited to dispose of it in ordinary trash cans. For more details, please
follow the local laws and regulations on battery recycling and disposal.
If the battery cannot be fully discharged due to a product failure, please do not dispose of the
battery directly in the battery recycling bin. In such a case, you should contact a professional
battery recycling organization for further processing.
The Lithium Cube contains materials that are prohibited from being placed in landfills and
require recycling. These include batteries, and some components in the inverter. Contact local
authorities for disposal/recycling instructions.