PerfectPower
Connecting the inverter
23
Fasten the inverter as follows (fig.
5
, page 5):
➤
Clip two holders on the lower left bar and two on the right.
You can move the holders as required.
➤
Fasten the inverter by screwing one screw through each hole in the hold-
ers.
6.2
Connecting the PP152 and PP154
The inverter is connected via a plug connected to a 12 V socket (PP152) or
a 24 V supply (PP154). The middle pin of the plug (fig.
1
4, page 3) must be
connected to the positive wire and the two side brackets of the plug (fig.
1
5,
page 3) must be connected to the negative wire.
a
Caution
Make sure the plug is firmly connected in the socket. If the connec-
tion is loose, the plug may heat up.
e
Caution
The rating of the socket, the supply cable and the fuse must be at
least 15 amps. Do not put in a fuse with a higher rating.
6.3
Connecting the PP402, PP404, PP602 and PP604
a
Caution
To set up the inverter, connect the red cable (fig.
1
4, page 3) to
the positive pole (+) of the battery and the black cable (fig.
1
5,
page 3) to the negative pole (–) of the battery. Make sure the bat-
tery poles are clean when connecting the terminals.
a
Caution
Only extend the connection line with cables with an equal or greater
cross section.
e
Caution
Do not reverse the polarity. Reversing the polarity of the connec-
tions will cause a great spark and the internal fuses will melt.
_PP150_PP400_PP600.book Seite 23 Donnerstag, 12. November 2009 2:25 14