![Waeco MSP 702 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/waeco/msp-702/msp-702_instruction-manual_3147653051.webp)
SinePower
Using the inverter
51
11.1
Set energy saving mode (Standby)
In energy saving mode, the inverter does not release any voltage, thereby
preserving the battery. If a connected appliance requires power which is
more than the pre-set power value, the inverter reverts to normal operation.
You can switch to energy-saving mode using the DIP switches S1, S2 and
S3 (fig.
3
1, page 4) and set the power value.
The switch positions for your inverter can be found in the following table:
11.2
Switch between 50 Hz and 60 Hz.
The output voltage can be switched between 50 Hz and 60 Hz with the DIP
switch S4 (fig.
3
1, page 4).
e
Warning!
Only adjust the S4 DIP switch when the respective frequency for
the output voltage should be used.
Set the S4 DIP switch (fig.
3
1, page 4) according to the following table:
Energy-saving mode up to
DIP switch
MSP 702
MSP 704
MSP 1012
MSP 1024
MSP 1512
MSP 1524
MSP 2012
MSP 2024
MSP 2512
MSP 2524
S1
S2
S3
Power
Off
Off
Off
Off
Off
Off
15 W
20 W
40 W
On
Off
Off
25 W
40 W
80 W
Off
On
Off
40 W
55 W
125 W
On
On
Off
50 W
75 W
170 W
Off
Off
On
65 W
95 W
210 W
On
Off
On
75 W
115 W
245 W
Off
On
On
85 W
135 W
280 W
On
On
On
Output voltage frequency
S4 DIP switch
50 Hz
Off
60 Hz
On