PT2R
OPERATION
1A
1A-9
k
2
k
1
h
2
i
j
1006SD78
1006SD79
1006SD77
1006SD75
1006SD72
1006SD73
g
1
FUEL
h
1
CHOKE
THROTTLE
g
2
1.13 To Start
1. Open fuel valve by moving lever down
(g
1
)
.
Note:
If engine is cold, move choke lever to close
position
(h
1
)
. If engine is hot, set choke to open
position
(h
2
)
.
2. Open throttle by moving it to the right
(k
1
)
.
3. Pull starter rope
(i)
.
Note:
If the oil level in the engine is low, the engine will
not start. If this happens, add oil to engine.
4. Open choke as engine warms
(h
2
)
.
5. Open throttle fully to operate pump.
1.15 Operation
Pump should begin pumping water within a minute
depending on length of suction hose and height of pump
above water. Longer hoses will require more time.
If pump does not prime, check for loose fittings or air leak
in suction hose. Make sure strainer in water is not
blocked.
Run engine at full speed while operating pump.
1.14 To Stop
1. Reduce engine RPM to idle by moving throttle com-
pletely to the left
(k
2
)
.
2. Press stop button
(j)
until engine comes to a complete
stop.
3. Close fuel valve
(g
2
)
.
DO NOT
pump flammable fluids, corrosive chemi-
cals or fluids containing toxic substances. These
fluids can create potentially dangerous health and
environmental hazards. Contact local authorities
for assistance.
WARNING
!