![Wacker Neuson PT2R Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/wacker-neuson/pt2r/pt2r_operators-manual-and-parts-book_3233112020.webp)
1A
OPERATION
PT2R
1
1A-14
1.26 Cleaning Fuel Strainer
Turn fuel valve off. Remove strainer cup
(c)
, seal
(d)
and
strainer
(e)
. Wash them thoroughly in a nonflammable
solvent. Dry them and install. Turn fuel valve on and
check for leaks.
1.25 Cleaning Pump
After pumping water containing a large amount of dirt or
debris, clean out inside of pump housing.
1. Remove drain plug
(a)
from pump housing and drain
any water left in pump.
2. Loosen the four knobs holding the pump cover
(b)
and remove cover.
3. Clean out dirt and debris. Inspect impeller and volute
insert for wear.
b
a
1033SD83
1006SD76
c
d
e
The impeller may develop sharp edges. Use care
when cleaning around impeller to prevent getting
cut.
WARNING
!