12 Technical data
34
100_0101_td_0014.fm
12.6
Extension cable
Only use permitted extension cables, see chapter
Safety
.
Refer to the following table for the required cross-section area of the extension cable:
WARNING
Electrical voltage.
Injuries from electrocution.
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data
).
NOTES
Refer to the nameplate or the chapter
Technical data
(via the item number) for the type
designation and voltage rating of your machine.
Machine
Voltage [V]
Extension [m]
Cross-section area of cable [mm
2
]
IREN30
42 3~
< 35
1,5
< 58
2,5
< 91
4
IREN38
42 3~
< 29
2,5
< 45
4
250 3~
< 150
1,5
IREN45
42 3~
< 20
2,5
< 32
4
< 46
6
250 3~
< 150
1,5
IREN58
42 3~
< 12
2,5
< 18
4
< 27
6
< 42
10
250 3~
< 150
1,5
IREN65
42 3~
< 8
2,5
< 13
4
< 19
6
< 29
10