![Wacker Neuson IREN Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/wacker-neuson/iren/iren_operators-manual_3240613023.webp)
10 Troubleshooting
100_0101_ts_0002.fm
23
10 Troubleshooting
Potential faults, their causes and remedies can be found in the following table.
Malfunction
Cause
Remedy
Vibrator head does not vibrate.
No line voltage.
Connect the plug to the in-
verter.
Check power cable for dam-
age, replace if defective.*
*
Have these tasks carried out by the service department of your Wacker Neuson representative per-
son.
Vibrator head has switched off
due to excess temperature.
Deactivate the machine and al-
low the vibrator head to cool
down.
ON/OFF switch defective.
Mechanical defect in the vi-
brator head.
Have the machine repaired. *
Noticeable sound, vibrator head
runs with reduced power.
One of the thermal overload
protections has switched off
(two phase operation).
Have the machine repaired. *