6 Components and operator's controls

100_0101_cp_0004.fm

15

6

Components and operator's controls

IREN30

IREN38, 45, 58, 65

IREN ST1

Item

Description

Item

Description

1

Vibrator head

4

Power cable

2

Protective hose

5

Plug

3

Switch housing

6

ON/OFF switch

Item

Description

Item

Description

1

Vibrator head

5

Plug

2

Protective hose

6

ON/OFF switch

3

Switch housing

7

Lower tube

4

Power cable

8

Rubber seal cap (optional)

Item

Description

Item

Description

1

Vibrator head

5

Power cable

2

Pipe

6

Plug

3

Protective hose

7

ON/OFF switch

4

Switch housing

8

Lower tube

Содержание IREN

Страница 1: ...Operator s manual Internal vibrator IREN Model IREN Document 5000203044 Issue 12 2019 Version 16 Language en...

Страница 2: ...of the statutory regulations in particular the protection of copyright will lead to civil and criminal prosecution Wacker Neuson Produktion GmbH Co KG is constantly working on the improvement of its p...

Страница 3: ...3 11 Behavior in dangerous situations 11 4 General safety instructions for power tools 12 5 Setup and function 14 5 1 Scope of delivery 14 5 2 Application 14 5 3 Functionality 14 6 Components and oper...

Страница 4: ...l is not a manual for extensive maintenance or repair work Such work should be carried out by Wacker Neuson service or by technically trained personnel The Wacker Neuson machine should be operated and...

Страница 5: ...ator s manual 2 3 Described machine types This operator s manual is valid for different machine types from a product range Therefore some figures can differ from the actual appearance of your machine...

Страница 6: ...tion that uniquely identifies your machine This information is needed to order spare parts and when requesting additional technical information Enter the information of your machine into the following...

Страница 7: ...red structural changes Opening the machine and the permanent removal of components Installing spare parts that do not originate from Wacker Neuson or are not comparable in the design system and qualit...

Страница 8: ...ne is to be stopped immediately and the competent supervisor is to be informed This supervisor shall make the following decisions and initiate everything required to eliminate the occurring danger If...

Страница 9: ...pplies if all machine parts are in a technically perfect condition The electric power supply must exhibit an intact grounded conductor connection PE and a protective earth contact 15 A 16 A and corres...

Страница 10: ...on Keep the machine clean Missing damaged or illegible safety warning labels should be replaced immediately Safety stickers contain important information for the protection of the operator Maintenance...

Страница 11: ...ing first aid and rescue facilities Keep access routes clear for emergency vehicles Make sure that employees receive first aid training Measures in the case of an emergency Immediately take the machin...

Страница 12: ...the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use personal protective equipment Always wear eye protection P...

Страница 13: ...ned users e Maintain power tools and accessories Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have...

Страница 14: ...ncy vibrations in the vibrator head Concrete is deaerated and compressed in the effective range of the vibrator head when the vibrator head is immersed into the fresh concrete The fresh concrete is si...

Страница 15: ...d 4 Power cable 2 Protective hose 5 Plug 3 Switch housing 6 ON OFF switch Item Description Item Description 1 Vibrator head 5 Plug 2 Protective hose 6 ON OFF switch 3 Switch housing 7 Lower tube 4 Pow...

Страница 16: ...r cable Note Do not kink the power cable 7 Secure the machine against falling or sliding Note Due to its length IREN ST may protrude over the means of transport Ob serve the valid road traffic regulat...

Страница 17: ...the construction site have the correct op erating voltage see nameplate of the machine or chapter Technical Data Check if mains or power distribution on the constructions site are protected in accord...

Страница 18: ...e via the ON OFF switch Switching IREN ST1 on 1 Use the pipe to hold the machine near the vibrator head 2 Switch on the machine via the ON OFF switch NOTICE Electrical voltage Incorrect voltage can ca...

Страница 19: ...ble if the vibrator head comes into contact with the concrete reinforcement The connection of the concrete to the reinforcement can be lost The machine can be damaged The result of the compacting depe...

Страница 20: ...6 Disconnect the machine from the inverter 8 4 Cleaning Cleaning the machine Clean the machine and all components with water after each use Note You can remove concrete residuals by immersing the runn...

Страница 21: ...part of the vibrator head assembly needs to be replaced fill it with sufficient oil Secure the lower part of the vibrator head assembly according ly Have this work performed by the service department...

Страница 22: ...imum diameter of vibrator head L Length of vibrator head LL Wear is highest at the immersed end of the vibrator head Dimensions in bold are wear dimensions Dimensions in brackets are original dimensio...

Страница 23: ...if defective Have these tasks carried out by the service department of your Wacker Neuson representative per son Vibrator head has switched off due to excess temperature Deactivate the machine and al...

Страница 24: ...xclusively for commercial use a so called B2B device according to the WEEE directive Unlike equipment mostly used in private households so called B2C devices this machine may therefore not be disposed...

Страница 25: ...e m ft 15 49 Weight kg lb 8 7 19 2 13 0 28 7 17 1 37 7 Plug CEE 32A 3P 4H 42V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 005 Class rating lll Protection class IP 67 Sw...

Страница 26: ...r cable m ft 15 49 Weight kg lb 10 5 23 1 14 7 32 4 24 2 53 3 Plug CEE 32A 3P 4H 42V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 008 Class rating lll Protection class I...

Страница 27: ...0 6 23 4 21 75 47 9 Plug CEE 16A 4P 10H 250V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 008 Class rating l Protection class IP 67 Switch off temperature C F 150 Storag...

Страница 28: ...cable m ft 15 49 Weight kg lb 11 8 26 0 16 0 35 3 25 2 55 5 Plug CEE 32A 3P 4H 42V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 008 Class rating lll Protection class IP...

Страница 29: ...11 9 26 2 22 25 49 1 Plug CEE 16A 4P 10H 250V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 008 Class rating l Protection class IP 67 Switch off temperature C F 150 Stora...

Страница 30: ...t 15 49 8 26 Weight GV kg lb 16 2 35 7 23 3 51 2 25 9 57 1 34 1 75 2 Plug CEE 32A 3P 4H 42V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 012 Class rating lll Protection...

Страница 31: ...ight kg lb 16 4 36 1 31 85 70 2 27 0 59 5 Plug CEE 16A 4P 10H 250V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 012 Class rating l lll Protection class IP 67 Switch off...

Страница 32: ...m ft 15 49 Weight kg lb 22 5 49 6 26 1 57 5 Plug CEE 32A 3P 4H 42V Engine type Asynchronous motor Oil specification 4 UH1 46N Oil quantity l 0 012 Class rating lll Protection class IP 67 Switch off te...

Страница 33: ...g lb 26 1 57 5 34 3 75 6 Plug CEE 32A 3P 4H 42V Engine type Asynchronmotor Oil specification 4 UH1 46N Oil quantity l 0 012 Class rating lll Protection class IP 67 Switch off temperature C F 150 Stora...

Страница 34: ...ables for which grounded conductors are connected to the plug and the coupling only for machines of class rating I see chapter Technical Data NOTES Refer to the nameplate or the chapter Technical data...

Страница 35: ...e of 42 V According to the table the extension cable must feature a cross section area of 4 mm2 Machine Voltage V Extension ft Cross section area of cable AWG IREN30 42 3 102 16 160 14 249 12 385 10 I...