Operation
HI400HD D / HD G
4.26
High and Low Voltage Protection (G Models)
Serial Number
Range
20105810 and higher
Introduction
Your machine is equipped with a control board that offers high and low voltage
protection. This enhanced control board controls burner operation when the
voltage drops or spikes for prolonged periods. If you wish to install this enhanced
control board on a machine outside the serial number range listed above, contact
Wacker Neuson.
Operation
During high and low voltage conditions, machines equipped with this feature
operate as shown in the table below.
Note:
The machine can not be reset while the operating status indicator is blinking
orange.
Overriding
restart delay
To override the 2 minute delay for restarting the machine after the voltage rises
above 90 VAC, remove the plug from the power receptacle and immediately plug it
back in. If the problem persists, contact Wacker Neuson.
If the Voltage:
Duration
Action
Drops below 90 VAC
10 seconds
Shuts down machine and initiates a
blinking orange operating status indicator.
Rises above 90 VAC
2 minutes
Restarts machine.
Rises above 147 VAC
—
Shuts down machine immediately.
Drops below 147 VAC
—
Restarts the machine immediately.
Содержание HI400HD D
Страница 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Страница 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Страница 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Страница 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Страница 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Страница 92: ......
Страница 94: ......