ghi_tx001464gb_FM10.fm
62
Setting up the Burner
HI400HD D / HD G
(See topic
Checking/Adjusting the Gas Pressure
.)
8. Conduct a smoke spot test. Follow the smoke spot tester manufacturer’s
instructions and the general guidelines below.
■
Use the access hole in the exhaust stack.
■
Several samples should be taken as the heater warms.
■
The final sample should be taken just before the heater reaches 71°C (160°F).
9. Analyze the combustion. Follow the combustion analyzer manufacturer’s
instructions and the general guidelines below.
■
Use the access hole in the exhaust stack.
■
Take several samples as the heater warms.
■
Take the final sample just before the heater reaches 71°C (160°F).
10.Re-adjust the air band, if necessary, until the smoke spot test and combustion
analysis are within the following parameters:
■
O
2
content: 3–5%
■
Smoke spot: less than 1
Result
The burner has now been set.