ghi_tx001462gb_FM10.fm
38
Operation
HI400HD D / HD G
4.11
Recommended Fuels and Fuel Blending Guide
Low ambient temperatures cause diesel fuels to gel. Gelled fuels will cause burner
ignition failure and/or burner fuel pump damage. Always use the proper fuel for the
conditions.
NOTICE:
Do not use B20 or any other type of biodiesel fuel in this machine.
4.12
Inspecting the Fuel Hose
When
Visually inspect the fuel hose assembly each time before operating the heater.
Replacement
hose
Replace a damaged hose assembly with an equivalent as specified on the
machine label.
Fuel Blend Guide
Lowest expected ambient
temperature °F (°C)
Generator powered
Shore powered
Below 5 (-15)
50-50 blend of #2 diesel
and #1 diesel, plus
additives
OR
50-50 blend of #2 diesel
and K1 kerosene, plus
additives
100% #1 diesel, plus
additives
OR
100% K1 kerosene,
plus additives
5 to 25 (-15 to -4)
70-30 blend of #2 diesel and #1 diesel, plus additives
OR
70-30 blend of #2 diesel and K1 kerosene,
plus additives
Above 25 (-4)
Winter-blend diesel
CAUTION
Fire hazard.
►
Do not use gasoline, crankcase oil, or any oil containing gasoline.
WARNING
Fire and explosion hazards. A damaged hose may leak flammable fuel.
►
Do not operate the heater if the hose has excessive abrasions, wear, or cuts.
Содержание HI400HD D
Страница 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Страница 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Страница 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Страница 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Страница 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Страница 92: ......
Страница 94: ......