4.28
Installing and Using the Remote Thermostat
Requirements
■
Remote thermostat
■
Pre-starting checks complete
Procedure
Perform the procedure below to install and use the remote thermostat.
1. Remove the thermostat receptacle plug
(a)
from the control panel receptacle.
2. Connect the remote thermostat
(b)
to the control panel receptacle
(c)
.
3. Set the sensor end
(d)
within the area to be heated.
4. Adjust the target temperature with the dial
(e)
.
Thermostat
adapter
An adapter is available to convert the proprietary thermostat connection to an
Edison plug-style connection for use with commonly available thermostats. This
adapter can be purchased using Wacker Neuson part #5200007098.
NOTICE:
The thermostat adapter is designed for use ONLY with a thermostat. To
avoid damaging the machine, do not plug any other equipment into the thermostat
adapter.
wcghi_gr007373
c
b
a
b
e