Genset Maintenance
HI 770XHD
8.2
Checking the Engine Oil
Requirements
Generator shut down
Engine cool
Machine positioned on a level surface
Engine oil API grade CF or higher
Determine engine oil type according to the ambient temperature.
Procedure
Perform the procedure below to check the engine oil.
1. Stop the engine and allow it to cool.
2. Remove the dipstick
(1)
.
3. Wipe the dipstick clean and reinstall it.
4. Check the engine oil level on the end of the dipstick. It must be within range
(A)
.
5. If the oil level is low, remove the filler plug
(2)
and add oil through the filler
opening until the level is within the range on the end of the dipstick.
NOTICE:
Do not operate a diesel engine when it is overfilled with engine oil. This
could result in engine damage or malfunction. Drain the appropriate amount of
engine oil from an over-filled diesel engine before operating it.
NOTICE:
When using engine oil of a different brand from the previous brand used,
drain all the previous engine oil before adding the new engine oil.
Result
The engine oil has now been checked.
above 25°C (77°F)
0 to 25°C (32 to 77°F)
below 0°C (32°F)
SAE30 or
SAE20 or
SAE10W or
SAE10W-30
SAE10W-40
SAE10W-30
SAE10W-40
SAE10W-30
SAE10W-40
wc_gr008359
wc_gr008824
1
2
A
Содержание HI 770XHD
Страница 1: ...5200003388 04 0212 5 2 0 0 0 0 3 3 8 8 Operator s Manual IDF Heater HI 770XHD EN...
Страница 8: ...Table of Contents HI 770XHD wc_bo5200003388_04TOC fm 8...
Страница 104: ...wc_tx001887gb fm 104 Schematics HI 770XHD 11 Schematics 11 1 AC Circuit...
Страница 106: ...wc_tx001887gb fm 106 Schematics HI 770XHD 11 4 DC Circuit...
Страница 111: ......