background image

wc_si000624gb.fm

11

GV 3800A

Safety Information

„

Always keep the machine at least one meter (three feet) away from structures, 
buildings, and other equipment during use.

„

Always keep the area immediately surrounding and underneath the machine 
clean, neat, and free of debris and combustible materials. Make sure that the 
area overhead is clear of debris that could fall onto or into the machine or 
exhaust compartment.

Safety 

devices, 

controls, and 

attachments

Only operate the machine when:

„

All safety devices and guards are in place and in working order.

„

All controls operate correctly.

„

The machine is set up correctly according to the instructions in the Operator’s 
Manual.

„

The machine is clean.

„

The machine’s labels are legible.

To ensure safe operation of the machine:

„

Do not operate the machine if any safety devices or guards are missing or 
inoperative.

„

Do not modify or defeat the safety devices. 

„

Only use accessories or attachments that are approved by Wacker Neuson.

Safe 

operating 

practices

When operating this machine:

„

Remain aware of the machine’s moving parts. Keep hands, feet, and loose 
clothing away from the machine’s moving parts.

When operating this machine:

„

Do not operate a machine in need of repair.

„

Never operate the generator, or tools attached to the generator, with wet hands.

„

Never enclose or cover the generator when it is in use or when it is hot.

„

Do not overload the generator. The total amperage of the tools and equipment 
attached to the generator must not exceed the load rating of the generator. 

„

Never stand on the machine.

Personal 

Protective 

Equipment 

(PPE)

Wear the following Personal Protective Equipment (PPE) while operating this 
machine:

„

Close-fitting work clothes that do not hinder movement

„

Safety glasses with side shields

„

Hearing protection

„

Safety-toed footwear

Installing as 

backup power

Special hazards exist when installing this machine as a backup power supply. 
Improper connection of generator to a building’s electrical system can allow 
electrical current from the generator to backfeed into utility lines. This may result in 
electrocution of utility workers, fire, or explosion. 

Содержание GV 3800A

Страница 1: ...5200003450 01 1011 5 2 0 0 0 0 3 4 5 0 Operator s Manual Portable Generator GV 3800A EN...

Страница 2: ...distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights Violators will be prosecuted Trademarks All trademarks referenced in this manual are...

Страница 3: ...r your own safety and to reduce the risk of injury carefully read understand and observe all instructions described in this manual Wacker Neuson expressly reserves the right to make technical modifica...

Страница 4: ...service center according to written instructions published by Wacker Neuson Unapproved parts attachments and modifications are those that do not meet the approved criteria Unapproved parts attachments...

Страница 5: ...nd Transporting 20 4 Operation 21 4 1 Recommended Fuel 22 4 2 Refueling the Machine 23 4 3 Determining Power Requirements 24 4 4 Installation 25 4 5 Installing the Spark Arrester 25 4 6 Generator Dera...

Страница 6: ...ical Data 42 7 1 Generator 42 7 2 Engine 43 8 Emission Control Systems Information and Warranty 44 8 1 Emission Control System Background Information 44 8 2 Limited Defect Warranty for Exhaust Emissio...

Страница 7: ...personal hazards f Obey all safety messages that follow this symbol DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury f To avoid death or seriou...

Страница 8: ...ts that are incompatible with the generator output Overloading the generator with a load that draws excessive power during either continuous running or start up Operating the generator in a manner tha...

Страница 9: ...replaced as necessary Do not use plugs or or cords that show signs of damage such as broken or cracked insulation or damaged blades Cleaning When cleaning and servicing the machine Keep the machine cl...

Страница 10: ...from the machine Remain aware of changing positions and the movement of other equipment and personnel in the application area job site Be aware of the application area Do not operate the machine in ar...

Страница 11: ...cker Neuson Safe operating practices When operating this machine Remain aware of the machine s moving parts Keep hands feet and loose clothing away from the machine s moving parts When operating this...

Страница 12: ...in the machine is well grounded and securely fastened to a good earthen ground per national and local regulations Always remove all tools cords and other loose items from the generator before starting...

Страница 13: ...rator away from the spill and wipe the generator dry before starting Do not smoke while operating the machine Cleaning When cleaning and servicing the machine Keep the machine clean and free of debris...

Страница 14: ...derstand the service procedures before performing any service to the machine All adjustments and repairs must be completed before operation Do not operate the machine with a known problem or deficienc...

Страница 15: ...lift or hold the machine safely See chapter Technical Data Remain aware of the location of other people when lifting the machine Make sure the transporting vehicle has sufficient load capacity and pla...

Страница 16: ...Label Meanings Wacker Neuson machines use international pictorial labels where needed These labels are described below A DANGER No sparks flames or burning objects near machine Shut off the engine be...

Страница 17: ...n electrocution of utility work ers fire or explosion Connections to a build ing s electrical system must be made by a qualified electrician and comply with all applica ble laws and electrical codes D...

Страница 18: ...the fuel flow valve E Electrical ground F DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon mon oxide This is a poison you cannot see or smell NEVER use inside...

Страница 19: ...on this nameplate so it will be available should the nameplate become lost or damaged When ordering parts or requesting service information you will always be asked to specify the model number item nu...

Страница 20: ...tached securely and has enough weight bearing capacity to lift or hold the generator safely Remain aware of the location of other people nearby when lifting the generator Transporting the Machine Obse...

Страница 21: ...Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide CO This is a poison you cannot see or smell If you can smell the generator exhaust you are breathing CO But...

Страница 22: ...uire this information to be posted on the fuel pump The following are Wacker Neuson approved percentages of oxygenates ETHANOL ethyl or grain alcohol 10 by volume You may use gasoline containing up to...

Страница 23: ...dure to refuel the machine is now complete WARNING Fire hazard Fuel and its vapors are extremely flammable Burning fuel can cause severe burns f Keep all sources of ignition away from the machine whil...

Страница 24: ...rer or dealer of the tool or appliance with questions regarding its power requirements NOTICE If a tool or appliance does not reach full speed within a few seconds when switched on turn it off immedia...

Страница 25: ...esent The surrounding area must be free from water and moisture All components must be protected from excessive moisture 4 5 Installing the Spark Arrester A spark arrester is available as an accessory...

Страница 26: ...e also affects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000...

Страница 27: ...or local agency having jurisdiction over electrical compliance If the generator is used at a construction site there may be additional regulations which must be observed In some areas generators are...

Страница 28: ...ss Damaged extension cords can cause electrical shock resulting in serious injury or death DO NOT use worn bare or frayed cords Replace damaged cords immediately Use the chart below as a guide for sel...

Страница 29: ...l Ref Description Ref Description a Engine switch e Main circuit breaker b Auto idle switch f Duplex receptacle 120V c Twist lock receptacle 120 240V g GFI test button d Voltage Selector Switch VSS h...

Страница 30: ...e the machine Consult an electrician for assistance 4 11 3 Press RESET button h The red LED should go out and the green LED should illuminate 4 11 4 Manually move the circuit breaker switch to the ON...

Страница 31: ...of the voltage selector switch when the main breaker is in the ON position This can cause arcing and can damage the generator Turn all tools and appliances off and place the main circuit breaker d in...

Страница 32: ...will not start 4 15 4 Fill the fuel tank to the red LEVEL ring only with fresh regular unleaded grade gasoline Do not overfill the fuel tank See section Technical Data NOTICE Fill the tank after placi...

Страница 33: ...on a2 4 16 3 Set the Auto Idle Switch c to OFF 4 16 4 Open the fuel valve d1 Note If the engine is cold move the choke lever to the closed position e2 If the engine is hot set the choke to the open po...

Страница 34: ...se the fuel valve d2 Note To stop the engine quickly in an emergency turn the engine switch to OFF b2 4 17 1 4 18 Emergency Shutdown Procedure Procedure If a breakdown or accident occurs while the mac...

Страница 35: ...ctiveness of the emission control system and may have a bearing on the outcome of a warranty claim 5 2 Periodic Maintenance Schedule Daily before starting After first 20 hrs Every 50 hrs Every 100 hrs...

Страница 36: ...h environmental protection legislation 5 3 3 Install the drain plug 5 3 4 Fill the engine crankcase with the recommended oil up to the level of the plug opening c See section Technical Data for oil qu...

Страница 37: ...es of low flash point solvents for cleaning the air cleaner A fire or explosion could result To service 5 4 1 Remove the air cleaner cover a Inspect the element b for holes or tears Replace the elemen...

Страница 38: ...e Do not touch the muffler while it is hot Note Refer to section Technical Data for the recommended spark plug type and the electrode gap setting 5 5 1 Remove the spark plug and inspect it 5 5 2 Repla...

Страница 39: ...39 5 6 Cleaning the Sediment Cup 5 6 1 Turn the fuel valve off 5 6 2 Remove the sediment cup a and the O ring b 5 6 3 Wash both thoroughly in a nonflammable solvent Dry and reinstall them 5 6 4 Turn...

Страница 40: ...in a well ventilated area DO NOT drain the fuel tank in an area with flames or sparks 5 7 3 Loosen the drain screw on the carburetor and drain any remaining fuel from the carburetor 5 7 4 Change the e...

Страница 41: ...engine are open Fuel tank has fuel Choke lever is in correct position Choke should be closed when starting a cold engine All loads are disconnected from generator Spark plug is in good condition Spark...

Страница 42: ...output W 3400 Type Single phase self exciting 2 pole field rotating AC voltages available Volts phase 120 240 1 Frequency Hz 60 Power factor cos 1 0 AC receptacles 125V duplex 2 125 250V twist lock Am...

Страница 43: ...GX 240 U1 VWS Max rated power rated speed kW Hp 5 3 7 1 3600 rpm Spark plug BPR6ES NKG Electrode gap mm in 0 7 0 8 0 028 0 031 Operating speed rpm 3600 Air cleaner type Oil wetted foam Engine lubrica...

Страница 44: ...time of purchase Exhaust Emissions The combustion process produces carbon monoxide oxides of nitrogen and hydrocarbons Control of hydrocarbons and oxides of nitrogen is very important because under ce...

Страница 45: ...ment is free of defects in materials and workmanship which would cause this engine equipment to fail to conform to EPA regulations during its warranty period Wacker Neuson is also liable for damages t...

Страница 46: ...e services after the item s first scheduled replacement as listed in the maintenance section of the engine equipment operator s manual such as spark plugs and filters Incidental or consequential damag...

Страница 47: ...you shall notify Wacker Neuson Product Support Department 1 800 770 0957 and you will be advised of the appropriate dealer service center where warranty repair can be performed All repairs qualifying...

Страница 48: ...charged for diagnostic labor that leads to determination that a warranted part is in fact defective provided that such diagnostic work is performed at a Wacker Neuson Corporation authorized service c...

Страница 49: ...ect or improper maintenance was the direct cause of the need for repair or replacement of the part That notwithstanding any adjustment of a component that has a factory installed and properly operatin...

Страница 50: ...Emission Control Systems Information and Warranty 50 wc_tx001772gb fm...

Страница 51: ...wc_tx001896gb fm 51 Notes GV 3800A...

Страница 52: ...Schematics GV 3800A 52 wc_tx001896gb fm 9 Schematics 9 1 Electrical Schematic A 14 22 12 18 25 16 5 7 17 6 6 8 19 21 11 10 13 20 15 1 2 4 3 B C wc_gr008687...

Страница 53: ...regulator 16 Voltage selector switch 5 20A circuit breaker 17 Twist lock receptacle 125 250V 6 Duplex receptacle 125V 18 Auto idle switch 7 GFCI 19 Idle solenoid 8 Engine ON OFF switch 20 Capacitor 21...

Страница 54: ......

Страница 55: ......

Страница 56: ...02 390 Wacker Neuson Production Americas LLC N92W15000 Anthony Ave Menomonee Falls WI 53051 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Neuson Limited Room 1701 03 1717 20 17 F Tower 1 G...