Troubleshooting
Problem / Symptom
Reason / Remedy
If engine does not start, check
that:
• Engine switch is on "Start".
• Fuel valves under fuel tank and on engine are open.
• Fuel tank has fuel.
• Choke lever is in correct position. Choke should be
closed when starting a cold engine.
• All loads are disconnected from generator.
• Spark plug is in good condition.
• Spark plug cap is tight.
• Engine oil level is adequate.
If engine starts but there is no
power at receptacles, check
that:
• Circuit breaker is closed.
• Connector from generator to control panel is tight.