background image

Labels

G 100 / G 120

26                                       

wc_si000546gb.fm

Y

Generator and Receptacle Wiring

Z

WARNING 
Electric shock at cooling fins.

AA

A nameplate listing the model number, item 
number, revision number, and serial number 
is attached to each unit. Please record the 
information found on this nameplate so it will 
be available should the nameplate become 
lost or damaged. When ordering parts or 
requesting service information, you will 
always be asked to specify the model 
number, item number, revision number, and 
serial number of the unit.

BB

This machine may be covered by one or 
more patents.

CC

DANGER 
Danger of asphyxiation! Do not operate this 
machine indoors. Electric shock and arc 
flash will cause serious injury or death. 

DD

NOTICE
Receptacles not used when:
Selector switch set to 208/120V and voltage 
greater than 228V.
Selector switch set to 480/277V and voltage 
greater than 457V.

UTILITY 159116

UTILITY 159116

U.S.PAT.Nos.: 6012285, 6471476, 

U.S.PAT.Nos.: 6012285, 6471476, 
D416858, D454357 OTHER U.S. AND 

D416858, D454357 OTHER U.S. AND 
FOREIGN PATENTS PENDING

FOREIGN PATENTS PENDING

Содержание G 100

Страница 1: ...5000185616 04 0911 5 0 0 0 1 8 5 6 1 6 Operator s Manual Mobile Generator G 100 G 120 EN...

Страница 2: ...distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights Violators will be prosecuted Trademarks All trademarks referenced in this manual are...

Страница 3: ...erstand and observe all instructions described in this manual Wacker Neuson expressly reserves the right to make technical modifications even without notice which improve the performance or safety sta...

Страница 4: ...Wacker Neuson Unapproved parts attachments and modifications are those that do not meet the approved criteria Unapproved parts attachments or modifications may have the following consequences Serious...

Страница 5: ...G 100 G 120 Foreword wc_tx000994gb fm 5...

Страница 6: ...Foreword G 100 G 120 6 wc_tx000994gb fm...

Страница 7: ...2 Labels 19 2 1 Label Locations 19 2 2 Label Meanings 21 3 Lifting and Transporting 31 3 1 Lifting the Machine 31 3 2 Towing the Machine 31 4 Operation 34 4 1 Refueling the Machine 35 4 2 Control Pan...

Страница 8: ...omatic Remote Start Up 59 4 26 Remote Transfer Switch 60 5 Using the LCD Panel and Keypad 61 5 1 Navigating the Menus 62 5 2 Entering Passwords 64 5 3 Adjusting Screen Contrast 65 5 4 Setting the Time...

Страница 9: ...7 5 Replacing the Racor Filter Element if equipped 80 7 6 Lubricating the Engine 81 7 7 Checking the Engine Coolant Level 82 7 8 Maintaining the Trailer 83 7 9 Storage 84 8 Basic Troubleshooting 85 9...

Страница 10: ...10 wc_bo5000185616_04TOC fm Table of Contents G 100 G 120...

Страница 11: ...cabinet As the engine runs the generator converts mechanical energy into electric power The operator connects loads to the electric power receptacles and connection lugs This is the safety alert symb...

Страница 12: ...s Using the machine as a ladder support or work surface Using the machine to carry or transport passengers or equipment Using the machine to tow other machines Operating the machine outside of factory...

Страница 13: ...Equipment PPE Wear the following Personal Protective Equipment PPE while operating this machine Close fitting work clothes that do not hinder movement Safety glasses with side shields Hearing protect...

Страница 14: ...als Make sure that the area overhead is clear of debris that could fall onto or into the machine or exhaust compartment 1 3 18 Make sure the machine is on a firm level surface and will not tip roll sl...

Страница 15: ...present Move the machine away from the spill and wipe the machine dry before starting Refueling safety When refueling the engine Clean up any spilled fuel immediately Refill the fuel tank in a well ve...

Страница 16: ...vehicle hitch Tires and wheels Before towing follow the instructions below to ensure that the tires and wheels are ready for use Check the tires on the trailer for tread wear proper inflation and con...

Страница 17: ...the control panel This will notify everyone that the unit is being serviced and will reduce the chance of someone inadvertently trying to start the unit If the unit is connected to a remote start or...

Страница 18: ...ose clothing away from the moving parts of the generator and engine 1 6 11 Replace all guards fasten doors and make sure all safety devices operate properly after making repairs or servicing the equip...

Страница 19: ...Arc flash hazard Turen schliessen Zugang kann elektrischen Schlag oder Verletzung verursachen Gefahr Kurzschlusslichtbogen Fermer les portes d acces ou il pourrait en resulter risque d electrocution o...

Страница 20: ...sque d electrocution ou accidents de personne Danger Arco de court circuit Danger Arco de court circuit Cierre las puertas Ya que de orto modo existe el peligro Cierre las puertas Ya que de orto modo...

Страница 21: ...ion B WARNING Pressurized contents Do not open when hot C WARNING Read and understand the supplied Operator s Manual before operating the machine Failure to do so increases the risk of injury to yours...

Страница 22: ...o prevent hearing loss wear hearing protection Hand injury if entangled in moving belt Rotating machinery Do not reach inside with engine running WARNING Hot surface NOTICE Avoid spraying water into g...

Страница 23: ...k of electrical shock and arc flash read the Operator s Manual Improper connection of the generator to a building s electrical system can allow electrical current from the generator to backfeed into u...

Страница 24: ...wc_si000546gb fm P Q QA Operator s Manual must be stored on machine Replacement Operator s Manual can be ordered through your local Wacker Neuson distributor R Remote start operation Read Operator s M...

Страница 25: ...D NC RED NC EMERGENCY STOP SWITCH VIO RED RED RED RED 10AWG GRN YEL BAT 2 80 83 84 85 RUN MODE 29 REMOTE START 28 MODE BREAKER 30 TRIPPED PLUG 2 CONTACT INPUTS TRIP BREAKER 56 E STOP 47 REMOTE ANNUNCI...

Страница 26: ...to specify the model number item number revision number and serial number of the unit BB This machine may be covered by one or more patents CC DANGER Danger of asphyxiation Do not operate this machine...

Страница 27: ...system if equipped JJ Certification Label VIN Number Also attached to each unit is a Certification Label This label specifies that the trailer conforms with all Federal Motor Vehicle Standards in effe...

Страница 28: ...engine NOTICE Do not use the battery disconnect switch while engine is running Damage to the electrical components may occur MM Fuses NN if equipped NOTICE Mobile generator must be level for proper o...

Страница 29: ...or neutral Starting in gear kills This label appears on the John Deere engine but does not apply to this machine SS Lug door must be closed for lugs and receptacles to energize TT Camlock models only...

Страница 30: ...Labels G 100 G 120 30 wc_si000546gb fm VV Camlock models only WARNING Electric shock and arc flash can cause serious injury or death...

Страница 31: ...or such work Lifting the generator A central lifting eye is located at the top of the generator and is attached to a lifting frame inside the housing When lifting the generator attach a hook or sling...

Страница 32: ...y braking the vehicle at a slow speed before entering traffic Both the vehicle and the trailer should brake smoothly If the trailer seems to be pushing check the fluid level in the surge brakes or the...

Страница 33: ...G 100 G 120 Lifting and Transporting wc_tx001191gb fm 33 Notes...

Страница 34: ...tandby or substitute power supply make sure the voltage and phase rotation of the line connections match those of the utility lines Failure to match phase rotation and voltage may cause equipment conn...

Страница 35: ...to refuel the machine is now complete WARNING Fire hazard Fuel and its vapors are extremely flammable Burning fuel can cause severe burns f Keep all sources of ignition away from the machine while ref...

Страница 36: ...fm 4 2 Control Panel wc_gr006136 m n u p v a c f b e g d o h k q r s t A HZ V R Basler DIAGNOSTICS DIAGNOSEN DIAGNOSTICOS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSEN DIAGNOSEN DIAGNOSTICOS DIAGNOSTI...

Страница 37: ...tion terminal lugs door f Engine start switch v Voltage selector switch g Keypad not required for operation 1 Right arrow button right forward h Circuit breaker 240V 50 Amp three 2 Up arrow button k C...

Страница 38: ...service to the generator unit make sure the main line circuit breaker is in the off O position NOTICE The convenience receptacles are not connected through the main line circuit breaker As a result t...

Страница 39: ...switch immediately launches the engine start cycle and activates the starter motor to crank the engine Off O position In the off O position power to the engine s electrical system including the fuel...

Страница 40: ...ine pre alarms Fuel Level 15 High Temperature 226 F Low Oil Pressure 20 psi Time to Service 250 hours Diagnostic Table Codes Active Engine Diagnostic Table Codes DTCs can be viewed in the menu See top...

Страница 41: ...Operation Select the voltage range by rotating the handle on the voltage selector switch to the desired voltage Locking the voltage selector The voltage selector is equipped with a locking mechanism T...

Страница 42: ...ck Switch The customer connection lugs panel access door is equipped with an interlock switch q When the door is opened this switch automatically trips the main circuit breaker Voltage to the receptac...

Страница 43: ...lso from the rest of the metering panel Operation Activate the emergency stop switch by pressing the red button Activating the emergency stop switch opens the main circuit breaker and the fuel solenoi...

Страница 44: ...chment of outside loads Connecting to the lugs Make connections to the lugs by running the power cables up through the slots in the bottom of the panel and into the lug Use a 5 16 inch or 8 mm Allen w...

Страница 45: ...comply with the National Electrical Code and other federal state and local regulations For grounding requirements in your area consult with a qualified electrician electrical inspector or local agency...

Страница 46: ...nytime the generator is running even with the main line circuit breaker open Operating notes When the voltage selector switch is in the 480V 3 position voltage at the duplex receptacles is 139V and vo...

Страница 47: ...er wheels Internal and pre operation checks check engine oil coolant and fuel levels fill as required check the fan belt and hoses on the engine for loose connections or fraying tighten or replace as...

Страница 48: ...MERGENCY STOP Pull out the emergency stop button after verifying the display and return the engine start switch to off O 7 Start engine by moving the engine start switch to the START RUN position 8 Af...

Страница 49: ...ng the voltage adjustment rheostat on the metering panel Check frequency The frequency should read 60 Hz wc_gr006140 v p k h f a 120 208 3 277 480 3 120 240 A HZ V R Basler DIAGNOSTICS DIAGNOSEN DIAGN...

Страница 50: ...hase mode the display will read L1 L3 or LL Amps A Displays the AC output amperage produced by the generator If the generator is operating at no load output amperage will display a 0 f A HZ V R Basler...

Страница 51: ...tput frequency This gauge should read approximately 60 Hz under a no load condition If the frequency is too high check the engine rpm Sample display with engine running Sample display in Auto mode A H...

Страница 52: ...s relative fuel level in the fuel tank Engine shuts down automatically at 5 level TEMPERATURE Displays temperature of engine coolant Engine shuts down automatically if coolant tem perature gets too hi...

Страница 53: ...25 C 77 F air intake temperature 40 C 104 F fuel inlet temperature Refer to the table below to estimate the engine power decrease in percent as environmental factors vary from the standard conditions...

Страница 54: ...CM has automatically shut the engine down OVERCRANK An overcrank fault is displayed when the engine fails to start during three cycles of the normal cranking cycle The ECM has automatically shut down...

Страница 55: ...fault 3 To clear the overload fault reset the main circuit breaker Failing to reset the main circuit breaker will cause the machine to shut down after 5 minutes The display will then change to OVERLO...

Страница 56: ...Make sure that the power shutdown will not create any hazards by turning off devices such as pumps heaters or lights that may need to be kept on 1 Remove all loads from generator 2 Open turn to off O...

Страница 57: ...ntake system The crankcase filter contains a high performance element which should be replaced after every 750 hours of operation See Replacing the Racor Filter Element in the Maintenance chapter Filt...

Страница 58: ...Terminal Block Location The remote run terminal block i is located just to the left of the convenience receptacle circuit breakers Description The remote run terminal block provides connection points...

Страница 59: ...complete the start circuit Wait for the engine to crank start and run Move the engine start switch to off O to stop the engine Remove the jumper wire from the remote run terminals after testing is com...

Страница 60: ...s supplied with the switch WARNING Electrocution hazard Failure to isolate the generator from the utility s electrical distribution system could cause output from the generator to backfeed into the ut...

Страница 61: ...certain machine settings if desired 5 0 1 The various monitoring and configuration menus can be accessed by pressing the right arrow button 1 This action brings up the Main Menu screen 5 0 2 To selec...

Страница 62: ...evel Total Run Time Settings General Settings Communications Generator Protection Breaker Management Bias Control Enter Password General Settings Crank Settings Alarm Status Alarms Pre Alarms Status I...

Страница 63: ...u Conf Elements Configurable elements Maintenance Reset Conf Prot Status Configurable protection status Metering Configure Date Time Oil Pressure Coolant Level Outputs Coolant Temp PF Power factor Coo...

Страница 64: ...ears with a blinking letter A as the default character Use the up down buttons 2 3 to change the A to the correct letter or number 5 2 2 When the correct letter or number appears press the right arrow...

Страница 65: ...4 three times to access the main menu 5 3 2 Using the up down arrow buttons 2 3 select SETTINGS and press the right arrow button 5 3 3 Select GENERAL SETTINGS Press the right arrow button 5 3 4 Selec...

Страница 66: ...to access the main menu 5 4 2 Using the up down arrow buttons 2 3 select SETTINGS and press the right arrow button 5 4 3 Select GENERAL SETTINGS Press the right arrow button 5 4 4 Select CONFIGURE DAT...

Страница 67: ...ight arrow button 5 5 5 Select SYSTEM UNITS Press the check mark button 5 5 5 6 If necessary enter your password See Entering Passwords for more information 5 5 7 Select either METRIC or ENGLISH defau...

Страница 68: ...hree times to access the main menu 5 6 2 Using the up down arrow buttons 2 3 select SETTINGS and press the right arrow button 5 6 3 Select ALARM CONFIGURATION Press the right arrow button 5 6 4 Select...

Страница 69: ...4 three times to access the main menu 5 7 2 Using the up down arrow buttons 2 3 select SETTINGS and press the right arrow button 5 7 3 Select SYSTEM PARAMETERS Press the right arrow button 5 7 4 Sele...

Страница 70: ...Number Item Number Revision and Serial Number is attached to each unit Please have this information available when contacting Wacker Neuson Note The illustrations shown in this chapter represent typic...

Страница 71: ...a can be installed if the machine is to be used in extremely cold weather The thermostat automatically powers the panel control module when the temperature drops to approximately 30 C 22 F This activa...

Страница 72: ...seconds coolant levels are still sensed as being low the ECM shuts down the engine The ECM will then display LOW COOL LEVEL Allow the engine to cool before adding additional coolant If it is necessar...

Страница 73: ...vel is the same as that measured by the engine dipstick A float inside the valve detects low oil levels and opens the valve to supply the needed oil The system is wired to the ECM and includes a low o...

Страница 74: ...cooling system As radiator coolant warms the wax pellet actuator engages a linkage c that opens the shutters As the coolant cools the shutters close 6 6 Lockable Battery Disconnect A lockable ON OFF...

Страница 75: ...amlock connectors for easy tool changes Each connector is protected by a spring loaded cover NOTICE Separate overcurrent protection must be provided Do not exceed 400 amps per receptacle WARNING Elect...

Страница 76: ...a on the curb side of the machine 2 Disconnect the internal feed hose d at the tank fitting and connect the internal feed hose to the external supply hose 3 The internal return hose e not shown is lo...

Страница 77: ...2 weeks Every 250 Hrs or 10 weeks Every 600 Hrs or 12 Mo Every 1200 Hrs or 24 Mo Every 2000 Hrs Other Check engine oil and coolant level 3 Check engine air filter gauge air cleaner dust cap 3 Visual...

Страница 78: ...hile viewing these menus press and hold the reset button 6 for 10 seconds If pre alarm is active Main screen METERING ALARM STATUS PRE ALARMS If pre alarm is not active METERING ENGINE METERING RUN ST...

Страница 79: ...tor of the engine air filter gauge reaches the red line Procedure Follow the procedure below to replace the primary air filter element 9 Remove the end cover d then discard the entire air filter cartr...

Страница 80: ...esent inside the canister so use caution to avoid spills 3 Pull the filter element down to remove it 4 Remove the O ring 5 from the top of the filter element end cap 7 Also remove the O ring 6 from th...

Страница 81: ...change of John Deere Engine Break In Oil and a new John Deere oil filter NOTICE Do not add more oil until the oil level is BELOW the ADD mark on the dipstick John Deere Engine Break In Oil TY22041 sho...

Страница 82: ...er cap seal for damage Clean the radiator filler cap or replace it if necessary 5 Re install the radiator filler cap NOTICE Solutions of antifreeze and supplemental coolant additives MUST be used year...

Страница 83: ...lug nuts immediately Axle Hubs Grease axle hubs using a good wheel bearing grease Brakes Check operation of brakes before each trip Check level of brake fluid in actuator at front of trailer at regul...

Страница 84: ...completing the procedures listed above fill the fuel tank completely and add a high quality stabilizer to the fuel Choose a stabilizer that includes cleaning agents and additives designed to coat prot...

Страница 85: ...fuel lines No generator output Main circuit breaker open Lug door open Voltage regulator malfunc tion Close main circuit breaker Close lug door Call for service Low oil pressure Low oil level Clogged...

Страница 86: ...fuel is not recommended Item No G 100 G 120 Engine Engine make John Deere 4 5L Engine model 4045HF285 Emissions Tier 3 Number of cylinders 4 Displacement cm in 4500 275 Engine speed rpm 1800 Rated po...

Страница 87: ...zag 277 480 120 208 120 240 AC voltages available 1 V 3 V 120 127 139 240 254 277 208 220 240 416 440 480 Frequency 60 Hz Power factor 1 3 1 0 0 8 Voltage regulation 1 00 Insulation class H Sound leve...

Страница 88: ...Skid Item No G 100 G 120 Generator Dry weight no trailer kg lbs 2131 4699 2143 4725 Operating weight no trailer kg lbs 2783 6137 2795 6163 Trailer weight without generator kg lbs 621 1370 GVWR kg lbs...

Страница 89: ...G 100 G 120 Technical Data wc_td000298gb fm 89 9 4 Dimensions G 100 G 120 a mm in 2784 110 0 b 1143 45 0 c 1727 68 0 wc_gr005086 b a c...

Страница 90: ...Technical Data G 100 G 120 90 wc_td000298gb fm Notes...

Страница 91: ...G 100 G 120 Schematics wc_tx000998gb fm 91 10 Schematics This page is intentionally left blank...

Страница 92: ...IP BREAKER 56 E STOP 47 E STOP 47 REMOTE ANNUNCIATOR REMOTE ANNUNCIATOR COMMON 51 COMMON 51 PREALARM 53 PREALARM 53 E STOP 46 E STOP 46 ALARM 52 ALARM 52 BAT 55 BAT 55 49 49 START START FUEL FUEL PRE...

Страница 93: ...Lug door safety switch 5 Fuses 25 Mechanical lugs 6 Hour meter 26 Relay if equipped 7 Shunt trip relay 27 Intake heater if equipped 8 Contact inputs 28 Starter relay 13 21 position connector 29 Starte...

Страница 94: ...Schematics G 100 G 120 94 10 3 Electrical Schematic 36 36 CT CT CT CT CT CT OR OR WHT WHT BR BR Y 6 6 7 7 7 7 PLUG 5 PLUG 5 CURRENT CURRENT TRANSFORMER TRANSFORMER CT CT CT CT C CT CT CT CT CT CT...

Страница 95: ...line voltage inputs 19 Terminal block 5 Shunt 20 Exciter 6 120V 20A GFI receptacle 21 Stator 7 120V breaker 22 Rotor 8 240V 50A breaker 23 Rectifier 10 240V 50A receptacle 24 Rotor winding 12 Engine c...

Страница 96: ......

Страница 97: ......

Страница 98: ...02 390 Wacker Neuson Production Americas LLC N92W15000 Anthony Ave Menomonee Falls WI 53051 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Neuson Limited Room 1701 03 1717 20 17 F Tower 1 G...

Отзывы: