Service Safety
A poorly maintained machine can become a safety hazard! In order
for the machine to operate safely and properly over a long period of
time, periodic maintenance and occasional repairs are necessary.
Personal Protective Equipment (PPE)
Wear the following Personal Protective Equipment (PPE) while
servicing or maintaining this machine:
•
Close-fitting work clothes that do not hinder movement
•
Safety glasses with side shields
•
Hearing protection
•
Safety-toed footwear
In addition, before servicing or maintaining the machine:
•
Tie back long hair.
•
Remove all jewelry (including rings).
1.6.1
Do not perform even routine service (oil/filter changes, cleaning,
etc.) unless all electrical components are shut down.
Before
servicing this machine, make sure the engine start switch is turned to
off “O”, the circuit breakers are open (off), the emergency stop switch
is closed (pushed in), and the negative terminal on battery is
disconnected. Attach a “DO NOT START” sign to the control panel.
This will notify everyone that the unit is being serviced and will reduce
the chance of someone inadvertently trying to start the unit. If the unit
is connected to a remote start or transfer switch, make sure the
remote switch is also off and tagged.
1.6.2
Ground Connection
The generator must be connected to a good earthen ground for
proper operating safety!
A central “equipment ground” is provided at the customer connection
lugs. This point is connected directly to the generator set base. All
other system grounds are connected to this central point. Ground the
generator in accordance with the standards defined in national, state,
and local regulations.
1.6.3
Do not attempt to open the radiator cap while the unit is running or
before the engine has cooled down. Severe burns may result!
1.6.4
Do not allow water to accumulate around the base of the machine. If
water is present, move the machine and allow the machine to dry
before servicing.
1.6.5
Do not service the machine if your clothing or skin is wet.
1.6.6
Do not allow untrained personnel to service this equipment. Only
trained electrical technicians should be allowed to service the
electrical components of this equipment.
WARNING
Содержание G 100
Страница 1: ...5000185616 04 0911 5 0 0 0 1 8 5 6 1 6 Operator s Manual Mobile Generator G 100 G 120 EN...
Страница 5: ...G 100 G 120 Foreword wc_tx000994gb fm 5...
Страница 6: ...Foreword G 100 G 120 6 wc_tx000994gb fm...
Страница 10: ...10 wc_bo5000185616_04TOC fm Table of Contents G 100 G 120...
Страница 33: ...G 100 G 120 Lifting and Transporting wc_tx001191gb fm 33 Notes...
Страница 90: ...Technical Data G 100 G 120 90 wc_td000298gb fm Notes...
Страница 91: ...G 100 G 120 Schematics wc_tx000998gb fm 91 10 Schematics This page is intentionally left blank...
Страница 96: ......
Страница 97: ......