94
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
18
1857
4 GIO
Component
IVTM
IVTM -
Under-
voltage/
Short Circuit
to Ground
The cable to the
IVTM has a short
circuit to ground.
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed.
- If no other fault can be
found, replace the connected
components.
18
2016
3 GIO
Component
Multiple
ITP
Func-
tions
Output
Speed
Signal -
Overvoltage/
Short to
Supply
Voltage
The cable to the
component on the
speed output has
a short circuit to
supply voltage.
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed.
- If no other fault can be
found, replace the connected
components.
18
2016
4 GIO
Component
Multiple
ITP
Func-
tions
Output
Speed
Signal -
Under-
voltage/
Short Circuit
to Ground
The cable to the
component on the
speed output has
a short circuit to
ground.
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed.
- If no other fault can be
found, replace the connected
components.
Содержание 400 500 320 0
Страница 148: ...148 Troubleshooting Fig 9 9 4017182a...
Страница 149: ...149 Troubleshooting Fig 9 10 4017180a...
Страница 150: ...150 Troubleshooting Fig 9 11 4017173a...
Страница 156: ...156 Troubleshooting Fig 9 15 4017183a...
Страница 157: ...157 Troubleshooting Fig 9 16 4017187a Fig 9 17 4012475b 3 2 SOLENOID VALVE CABLE P N 472 170 997 0 1 2...
Страница 174: ...174 Troubleshooting Fig 9 35 4017186a...
Страница 187: ...187 Notes Notes...