85
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
18
1664
6 GIO
Component
Multiple
ITP
Func-
tions
GIO_
Powerstage -
(PwrStage3)
Current
Too High
or Circuit
Grounded
Overload was
detected at GIO2
pin 1.
- Check whether water or
moisture has entered into the
connector/ dummy cap and
check the seals for proper
fi
t.
- Check whether a function
has been parameterised on
this slot in addition; if this is the
case, then:
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether the cable is
frayed.
18
1664
11
GIO
Component
Multiple
ITP
Func-
tions
GIO
Powerstage
Unknown load -
A load has been
detected on
GIO powerstage
3, that is not
parameterized.
- Check the parameter setting.
- Check whether the correct
cables are used.
- Verify connectors are
properly seated and have no
signs of moisture or corrosion.
- Check the cable between
modulator and the connected
component.
- Check whether the cable is
frayed.
- If no other fault can be
found, replace the connected
components.
18
1665
11
GIO
Component
Multiple
ITP
Func-
tions
GIO_
Powerstage -
(PwrStage3)
Unknown
Load
A component for
which there are no
parameter settings
was detected at
GIO2 pin 1.
- Check whether the cable to
the GIO Powerstage 3 or the
connected load is defective.
- Check whether the correct
cables are used.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
18
1680
1 GIO
Component
Multiple
ITP
Func-
tions
GIO_
Powerstage -
(PwrStage4)
Load Too
Low
Insuf
fi
cient current
consumption.
Check if correct
component is
installed on GIO2
pin 4.
- Check whether the cable to
the GIO Powerstage 4 or the
connected load is defective.
- Check whether the correct
cables are used.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
Содержание 400 500 320 0
Страница 148: ...148 Troubleshooting Fig 9 9 4017182a...
Страница 149: ...149 Troubleshooting Fig 9 10 4017180a...
Страница 150: ...150 Troubleshooting Fig 9 11 4017173a...
Страница 156: ...156 Troubleshooting Fig 9 15 4017183a...
Страница 157: ...157 Troubleshooting Fig 9 16 4017187a Fig 9 17 4012475b 3 2 SOLENOID VALVE CABLE P N 472 170 997 0 1 2...
Страница 174: ...174 Troubleshooting Fig 9 35 4017186a...
Страница 187: ...187 Notes Notes...