110
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
18
2752
6 Subsystem
Connection
ELEX
ELEX
Supply -
(CL30)
Current
Too High
or Circuit
Grounded
Overload was
detected at
subsystem pin
1 (cl.30) for
the Electronic
Extension Module.
- Check the cable between
modulator and the ELEX.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed .
- Please open the fault
memory dialogue ELEX and
follow the error information
there. Contact WABCO
customer service for further
help.
- If no other fault can be
found, replace the connected
components.
18
2752
11
Subsystem
Connection
ELEX
ELEX -
Internal
Failure
See diagnostic
memory of
the Electronic
Extension Module.
- Please open the fault
memory dialogue ELEX and
follow the error information
there.
- Contact WABCO customer
service for further help.
18
2752
12
Subsystem
Connection
ELEX
ELEX -
Pin Con-
fi
guration
Not Available
A pin is not
available in
the Electronic
Extension Module
or there is a
communication fault
to the Electronic
Extension Module.
- Possible the Electronic
Extension Module is not
connected or the cable to the
Electronic Extension Module is
defective.
- Other faults with the identical
operating hour may occur with
this fault.
Содержание 400 500 320 0
Страница 148: ...148 Troubleshooting Fig 9 9 4017182a...
Страница 149: ...149 Troubleshooting Fig 9 10 4017180a...
Страница 150: ...150 Troubleshooting Fig 9 11 4017173a...
Страница 156: ...156 Troubleshooting Fig 9 15 4017183a...
Страница 157: ...157 Troubleshooting Fig 9 16 4017187a Fig 9 17 4012475b 3 2 SOLENOID VALVE CABLE P N 472 170 997 0 1 2...
Страница 174: ...174 Troubleshooting Fig 9 35 4017186a...
Страница 187: ...187 Notes Notes...