Remove the cover in Teflon, clean the bar with alcohol and then apply the new Teflon cutting
the exceeding part to the two extremities. Put the bar in the guide and then connect the
cables.
8.
MAINTENANCE
1.
Before any cleaning, maintenance and repair operation, is needed to disconnect the outlet
from the general electrical system.
2.
The maintenance operations must be carried out from qualified people. For any repairs
operation, is needed to address to a
Technical Center Authorized from the WAAGE
s.r.l.
It’
is needed to use only original spare parts. A good vacuum and welding quality of the bags
depends on the cleaning of your. We recommend to control the conditions of the welding bar.
Do not use in any circumstances tools or knives in order to clean up the welding bar.
9. SOSTITUZIONE OLIO POMPA ( MODELLO SV 1
– 3 )
Procedure
Put off the device ignition switch and pull out the plug.
Unscrew the oil draining cap.
Let the oil drain away for at least 10 minutes.
Twist on the draining cap.
Remove the screw top loosening the 4 fixing screws.
Execute the oil replenishment above the half of the windowpane level.
It is advisable to replace oil at every 500 hours work.
Oil recommended by the manufacturer:
Lubricating oil for vacuum pumps BV 32
1 oil level pilot 4 oil replenishment cap
2 oil draining cap
3 oil draining grid