Remove 12 screws (1, Fig. 22) securing
platen cover assembly (2, Fig. 22) to
clamshell assembly.
Fig. 22
D.
Remove mounting clips (1, Fig. 23) securing
high limit capillary bulb to platen insulation
retainer (2, Fig. 23).
Fig. 23
5.
Reverse procedure to install.
When installing, do not bend and kink the
capillary tube or damage to the control may occur.
6.
Check for proper operation.
CONTROL THERMOSTAT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
2.
Remove control thermostat knob and remove 2
screws securing thermostat to control box
mounting shelf.
Fig. 24
3.
Note wire locations (1, Fig. 25) and disconnect
from control thermostat (2, Fig. 25).
Fig. 25
4.
Access control thermostat capillary bulb:
VMCS HEAVY DUTY ELECTRIC GRIDDLE TOP - REMOVAL AND REPLACEMENT OF PARTS
Page 9 of 19
F45571 (0316)