background image

– 6 –

OPERATION

WARNING:  THE CHARBROILER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN
OPERATING, CLEANING OR SERVICING THE CHARBROILER.

CONTROLS

Gas Valves

— Regulate gas flow to the burners.

Pilot Adjusting Valve

— Regulates gas flow to pilot burner.

Gas Pressure Regulator

— Regulates gas pressure to the burners.

LIGHTING INSTRUCTIONS

1. Turn gas shutoff valve and burner gas valves to the OFF position and wait 5 minutes.

2. Turn the gas shutoff valve to the ON position.

3. Turn pilot valve adjusting valve counterclockwise.  Light the pilot adjacent to each burner.  Adjust

the pilot screw until the pilot flame is 

1

/

4

" (6 mm) high.  The flame should have a slight yellow tip.

Light pilots through observation holes provided on front face of burner box.

4. Turn the burner gas valve to the ON position.

5. Air shutters on the burners must be individually adjusted to provide a blue flame.  Adjust all traces

of yellow out of the burner flame.

6. For complete shutdown, turn the gas shutoff valve, burner gas valves, and the pilot adjustment

valves to the OFF position.

7. To relight, follow steps 1-4.

GRATE POSITION

The cast iron grates are positioned to lay flat for stock pot use and for cleaning.  For broiling, reverse
grates to slope forward.  If you need an extra griddle for your rush hour periods, a lift-off griddle is
available as an optional extra.

PREHEATING

Allow charbroiler to preheat approximately 30 minutes with burners full-on.  Rub grates with grease
before using.  The excess grease will run forward and drip onto the front grease trough.

OPERATING THE CHARBROILER

1. Load charbroiler.

2. Turn burners down to prevent overheating which causes the meat to overchar.

3. Scrape the grates with a wire brush during broiling to keep the grates clean.  Do not allow debris

to accumulate on the grates.

4. Turn burners to low setting during slack periods to conserve energy.

Содержание VCB25S ML-44908Z

Страница 1: ...4908Z VCB25M ML 44963Z VCB36 ML 44966 VCB36S ML 44909Z VCB36C ML 44967 VCB36M ML 44964Z VCB47S ML 44910Z VCB47M ML 44965Z INSTALLATION OPERATION MANUAL FORM 31167 Jan 2001 VULCAN HART COMPANY P O BOX...

Страница 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Страница 3: ...mpany assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the charbroiler is found to be damaged save the pa...

Страница 4: ...Code ANSI NFPA 70 latest edition Copies may be obtained from The National Fire Protection Association Batterymarch Park Quincy MA 02169 7471 INSTALLATION CODES AND STANDARDS In Canada 1 Local codes 2...

Страница 5: ...SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be fully purged to remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds...

Страница 6: ...ndividually adjusted to provide a blue flame Adjust all traces of yellow out of the burner flame 6 For complete shutdown turn the gas shutoff valve burner gas valves and the pilot adjustment valves to...

Страница 7: ...ates may be laid in the flat position with burners full on to burn off fat and carbon When grates have cooled off brush thoroughly with a steel brush Remove grates and front grease trough for thorough...

Страница 8: ...MENDED SERVICE FREQUENCY Frequency of service maintenance will be largely dependent upon customer usage 10 12 hours operation per day 7 days a week Every 30 60 days 4 6 hours a day 5 days a week Every...