– 7 –

The charbroiler is a free-vented appliance.  All the products of combustion and the heat generated by
the burners pass through the grates.  When meat is placed on the grates, you are blocking the venting,
thus causing a temperature build-up.  The charbroiler, with a complete load, will operate most efficiently
with burners turned down 

1

/

3

 to 

1

/

2

.

DRIP PAN

DO NOT allow the drip pan to overflow.  Empty the drip pan when three-quarters full to reduce the
possibility of spillage.

CLEANING

Daily

Thoroughly scrape grate so that grease flows into front grease trough and drip pan.  This prevents flare-
ups.

Grates may be laid in the flat position with burners full on to burn off fat and carbon.  When grates have
cooled off, brush thoroughly with a steel brush.

Remove grates and front grease trough for thorough cleaning.

Remove and empty drip pan.  Clean as you would any normal utensil.  Rinse thoroughly and wipe dry
with a soft clean cloth.

Once charbroiler is clean, replace drip pan, grates, and front grease trough.

Clean stainless steel surfaces with a mild detergent and water, using a damp cloth, or with a
commercial stainless steel cleaner.  Rinse thoroughly and wipe dry with a soft clean cloth.

Burner ports and throats should be thoroughly cleaned.  Venturi must be free from grease and lint.  DO
NOT
 insert pick in burner port hole.

Burner with baffle may be removed periodically for cleaning (use a wire brush).

Содержание VCB25S ML-44908Z

Страница 1: ...4908Z VCB25M ML 44963Z VCB36 ML 44966 VCB36S ML 44909Z VCB36C ML 44967 VCB36M ML 44964Z VCB47S ML 44910Z VCB47M ML 44965Z INSTALLATION OPERATION MANUAL FORM 31167 Jan 2001 VULCAN HART COMPANY P O BOX...

Страница 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Страница 3: ...mpany assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the charbroiler is found to be damaged save the pa...

Страница 4: ...Code ANSI NFPA 70 latest edition Copies may be obtained from The National Fire Protection Association Batterymarch Park Quincy MA 02169 7471 INSTALLATION CODES AND STANDARDS In Canada 1 Local codes 2...

Страница 5: ...SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be fully purged to remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds...

Страница 6: ...ndividually adjusted to provide a blue flame Adjust all traces of yellow out of the burner flame 6 For complete shutdown turn the gas shutoff valve burner gas valves and the pilot adjustment valves to...

Страница 7: ...ates may be laid in the flat position with burners full on to burn off fat and carbon When grates have cooled off brush thoroughly with a steel brush Remove grates and front grease trough for thorough...

Страница 8: ...MENDED SERVICE FREQUENCY Frequency of service maintenance will be largely dependent upon customer usage 10 12 hours operation per day 7 days a week Every 30 60 days 4 6 hours a day 5 days a week Every...

Отзывы: