Vulcan-Hart VCB25S ML-44908Z Скачать руководство пользователя страница 2

– 2 –

IMPORTANT FOR YOUR SAFETY

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS
EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND
ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.

POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE
EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED
FROM THE LOCAL GAS SUPPLIER.

IMPORTANT

IN THE EVENT A GAS ODOR IS DETECTED, SHUT
DOWN UNITS AT MAIN SHUTOFF VALVE AND
CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.

WARNING

IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATING AND
MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.

IN THE EVENT OF A POWER FAILURE, DO NOT
ATTEMPT TO OPERATE THIS DEVICE.

© VULCAN-HART COMPANY, 2001

Содержание VCB25S ML-44908Z

Страница 1: ...4908Z VCB25M ML 44963Z VCB36 ML 44966 VCB36S ML 44909Z VCB36C ML 44967 VCB36M ML 44964Z VCB47S ML 44910Z VCB47M ML 44965Z INSTALLATION OPERATION MANUAL FORM 31167 Jan 2001 VULCAN HART COMPANY P O BOX...

Страница 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Страница 3: ...mpany assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the charbroiler is found to be damaged save the pa...

Страница 4: ...Code ANSI NFPA 70 latest edition Copies may be obtained from The National Fire Protection Association Batterymarch Park Quincy MA 02169 7471 INSTALLATION CODES AND STANDARDS In Canada 1 Local codes 2...

Страница 5: ...SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be fully purged to remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds...

Страница 6: ...ndividually adjusted to provide a blue flame Adjust all traces of yellow out of the burner flame 6 For complete shutdown turn the gas shutoff valve burner gas valves and the pilot adjustment valves to...

Страница 7: ...ates may be laid in the flat position with burners full on to burn off fat and carbon When grates have cooled off brush thoroughly with a steel brush Remove grates and front grease trough for thorough...

Страница 8: ...MENDED SERVICE FREQUENCY Frequency of service maintenance will be largely dependent upon customer usage 10 12 hours operation per day 7 days a week Every 30 60 days 4 6 hours a day 5 days a week Every...

Отзывы: