ER SERIES ELECTRIC FRYERS - TROUBLESHOOTING
F35613 (
September
2003)
Page 43 of 48
SOLID STATE OR COMPUTER
CONTROL HARNESS PIN-OUTS
PIN NO.
INPUTS
PIN NO.
OUTPUTS
3
C2-1
24VAC Hot
C2-8
24VDC (+) Heat Demand
C2-2
24VAC Neutral
1
C2-9
Not used at this time
2
C2-3
Probe High (red)
C2-10
24VDC (+) Right Basket Lift
C2-4
Probe Low (white)
C2-11
24VDC (+) Left Basket Lift
C2-5
Drain Valve Interlock (24VAC) N.O.
C2-12
No connection
C2-6
Heat Status (24VAC)
---
---
C2-7
Lift Relay DC (-) Common
---
---
NOTES:
1. Connected to ground internally. 2. Available for external buzzer output (24VDC).
3. Outputs to Control Interface Board.
CONTROL INTERFACE BOARD
PIN-OUTS
PIN NO.
INPUTS
PIN NO.
OUTPUTS
P1
24VDC (+) Left Basket Lift
P6
Heat Demand, Triac (24VAC)
2
P2
24VDC (+) Right Basket Lift
P7
System Ground
P3
24VDC (+) Heat Demand Control, Triac
P8
24VAC Right Basket Lift
3
P4
Lift Relay DC (-) Common
P9
24VAC Left Basket Lift
3
P5
Heat Demand, Triac (24VAC)
---
---
P10
Relay Contacts Common (24VAC)
1
---
---
NOTES:
1. Relays connected internally. 2. To R1 heat relay coil.
3. To basket lift relay coil.
FRYMATE (DUMP STATION)
WITH OPTIONAL HEATER
SYMPTOM
POSSIBLE CAUSES
No heat.
1. Unplugged.
2. Power switch off or inoperative.
3. Main circuit breaker off or open.
4. Malfunctioning heat assembly.
Содержание ERC50
Страница 24: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 24 of 48 COMPONENT LOCATION ...
Страница 25: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 25 of 48 POWER SUPPLY BOX ...
Страница 26: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 26 of 48 CIRCUIT BREAKER SUPPLY BOX ...
Страница 32: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 32 of 48 Heater Circuit ...
Страница 33: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 33 of 48 Basket Lift Circuit ...
Страница 35: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 35 of 48 ...
Страница 37: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 37 of 48 ...
Страница 38: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 38 of 48 Basket Lift ...
Страница 40: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 40 of 48 Frymate Dump Station ...
Страница 45: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 45 of 48 NOTES ...
Страница 46: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 46 of 48 NOTES ...
Страница 47: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 47 of 48 NOTES ...