background image

WARNING 

RISK OF FIRE

•  To reduce the risk of severe injury or death, follow all installation 

instructions.

‡&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU

•  Install the clothes dryer according to these instructions and in 

accordance with local codes.

•  

California Safe Drinking Water and Toxic Enforcement Act

    This act requires the governor of California to publish a list of 

substances known to the state to cause cancer, birth defects or other 

reproductive harm and requires businesses to warn customers of 

potential exposure to such substances. Gas appliances can cause 

minor exposure to four of these substances, namely benzene, 

carbon monoxide, formaldehyde and soot, caused primarily by the 

incomplete combustion of natural gas or LP fuels. Properly adjusted 

dryers will minimize incomplete combustion. Exposure to these 

substances can be minimized further by properly venting the dryer 

to the outdoors.

•  This dryer must be exhausted to the outdoors.

•  Use only rigid metal 4” diameter ductwork inside the dryer cabinet 

and use only UL approved transition ducting between the dryer and 

the home duct.

‡'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ

PDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLW

must be UL listed and installed in accordance with the instructions 

found in “Connecting The Dryer To House Vent” on page 5 of this 

manual. Flexible venting materials are known to collapse, be easily 

FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZ

DQGLQFUHDVHWKHULVNRI¿UH

•  Do not install or store this appliance in any location where it could 

be exposed to water and or weather.

•  

6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU

IN THE COMMONWEALTH OF MASSACHUSETTS
•  This product must be installed by a licensed 

SOXPEHURUJDV¿WWHU

•  When using ball-type gas shut-off valves, 

WKH\VKDOOEHWKH7KDQGOHW\SH

•  A flexible gas connector, when used, must 

QRWH[FHHGIHHW

Installation
Instructions

Gas Dryer

03

BEFORE YOU BEGIN

Read these instructions completely and 

FDUHIXOO\

• 

IMPORTANT-

 Save these instructions for 

local inspector’s use.

• 

IMPORTANT-

 Observe all governing codes 

and ordinances.

 Note to Installer -

 %H VXUH WR OHDYH WKHVH

instructions with the customer.

• 

Note to Customer -

 Keep these instructions with 

your Owner’s Manual for future reference.

‡ %HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU

discarded, remove the dryer door.

• Inspect the dryer exhaust outlet and straighten 

the outlet walls if they are bent.

•  Service information and the wiring diagram are 

located in the control console.

•  Do not allow children on or in the appliance. Close 

supervision of children is necessary when the 

appliance is used near children.

•  Install the dryer where the  temperature is above 

50°F for satisfactory operation of the dryer 

control system.

•  Product failure due to improper installation is not 

covered under the Warranty.

234D2217P003     31-16737    10-13  GE

LEVEL

8" PIPE WRENCH

10" ADJUSTABLE WRENCHES

 (x2)

TOOLS YOU WILL NEED

SLIP JOINT PLIERS

FLAT BLADE SCREWDRIVER

 

MATERIALS YOU WILL NEED

GLOVES

SAFETY

GLASSES

4" DUCT

CLAMPS (2)

OR

4" SPRING

CLAMPS (2)

EXHAUST

HOOD

4" DIA. METAL

ELBOW

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

DUCT TAPE

SOAP SOLUTION

FOR LEAK DETECTION

PIPE

COMPOUND

FLEXIBLE GAS LINE CONNECTOR

4XHVWLRQV"&DOO*(&$5(6RUYLVLWRXU:HEVLWHDW*($SSOLDQFHVFRP

 

,Q&DQDGDFDOORUYLVLWZZZ*($SSOLDQFHVFD

Summary of Contents for Moisture monitor series 3

Page 1: ...DOOHUV H VXUH WR OHDYH WKHVH LQVWUXFWLRQV ZLWK WKH FXVWRPHU IN THE COMMONWEALTH OF MASSACHUSETTS This product must be installed by a licensed SOXPEHU RU JDV WWHU When using ball type gas shut off valv...

Page 2: ...yer for use ZLWK SURSDQH 3 JDV 219 56 216 0867 0 3523 5 75 1 1 48 3 56211 1 IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE 5 48 5 0 176 The dryer must be disconnected from the gas supply piping system d...

Page 3: ...ors as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches APPLY PIPE...

Page 4: ...D RU DPS FLUFXLW EUHDNHU RU WLPH GHOD IXVH I HOHFWULFDO VXSSO SURYLGHG GRHV QRW PHHW WKH DERYH VSHFL FDWLRQV LW LV UHFRPPHQGHG WKDW D OLFHQVHG HOHFWULFLDQ LQVWDOO DQ DSSURYHG RXWOHW WARNING THIS DRYE...

Page 5: ...QRW XVH GXFW ORQJHU WKDQ VSHFL HG LQ WKH H KDXVW length table Longer ducts can accumulate lint FUHDWLQJ D SRWHQWLDO UH KD DUG Never install a screen in or over the exhaust duct This ZLOO FDXVH OLQW W...

Page 6: ...WDO OHQJWK RI H LEOH PHWDO GXFW VKRXOG QRW H FHHG IHHW P For many applications installing elbows at both the dryer DQG WKH ZDOO LV KLJKO UHFRPPHQGHG VHH LOOXVWUDWLRQV EHORZ OERZV DOORZ WKH GU HU WR VL...

Page 7: ...fastening devices which extend into the interior of the exhaust vent Provide an opening with a free area of at least 25 sq in for introduction of outside air into the dryer room Stacking of a gas drye...

Page 8: ...QJH RQ WKH RSSRVLWH VLGH ZKHUH RX UHPRYHG WKH OOHU SOXJV SSO UP SUHVVXUH WR JHW WKH VFUHZV VWDUWHG 2 Loosen the top screw from each hinge on the dryer face half way With one hand holding the top of th...

Reviews: