GRM SERIES GAS FRYERS
VULCAN-HART F-45385 Rev. C (9-15)
-11-
1.
Open the door.
2.
Make sure that thermostat is set to OFF. The thermostat is located behind the door.
3.
Push the gas control valve knob and turn to OFF (see figure below, view A). Wait 5
minutes for unburned gas to vent.
4.
Push and turn gas control valve knob to the
“L” in PILOT (see figure below, view B).
5.
While still holding the knob in, light the pilot with a lit flame. Continue to depress the
knob until pilot remains lit when knob is released. If the pilot does not remain lit, repeat
step 3 through 5.
6.
Depress and turn gas control knob to ON (See figure below, view C).
7.
If gas supply is interrupted, repeat steps 2 through 6.
TURNING ON THE FRYER
Set the temperature knob to desired temperature.
After the set temperature has been reached, the thermostat shuts off the gas flow
to burners.
The pilot remains lit. The burners will cycle on and off, maintaining the set
temperature.
TURNING OFF THE FRYER
1.
Turn the thermostat OFF.
2.
To keep the pilot lit, turn the gas valve to “L” in Pilot.
3.
To shut off all gas to the system, including the pilot, turn the gas valve knob to the
OFF position.