![VTS Medical Systems VTS2000 Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/vts-medical-systems/vts2000-series/vts2000-series_user-manual_1056180045.webp)
VTS2000 Series frequency inverter
- 43 -
F1.10
Reverse jog
frequency
setting
F1.11
Jog
acceleration
time
Jog acceleration and deceleration time setting
0.1
~
999.9S
0.4
~
4.0KW
10.0S
5.5
~
7.5KW
15.0S
Model
setting
○
F1.12
Jog
deceleration
time
F1.13
Jump
frequency
By setting the jump frequency and range, the
inverter can avoid the mechanical resonance point of
the load.
0.0
~
Upper limit
frequency
0.0Hz
○
F1.14
Jump range
0.0
~
10.0Hz
0.0Hz
○
F1.15
Combination
frequency
setting
method
0
:
Potenti digital frequency
1
:
Potenti digital frequency
2
:
Potenti AVI
3
:
Digital frequency 1 + AVI
4
:
Digital frequency 2 + AVI
0
~
7
0
×
Содержание VTS2000 Series
Страница 1: ...VTS2000 Series Frequency Inverter User Manual Controlling and protecting your motor...
Страница 14: ...VTS2000 Series frequency inverter 12 2 Installation and wiring 1 Dimensions...
Страница 16: ...VTS2000 Series frequency inverter 14 2 Basic wiring diagram...
Страница 21: ...VTS2000 Series frequency inverter 19 3 Operation panel introduction...
Страница 96: ......
Страница 111: ...VTS2000 Series frequency inverter 15 2 Instalacja i okablowanie 1 Wymiary...
Страница 113: ...VTS2000 Series frequency inverter 17 2 Podstawowy schemat po cze...
Страница 114: ...VTS2000 Series frequency inverter 18 3 Korespondencja skoczk w...
Страница 121: ...VTS2000 Series frequency inverter 25 3Wprowadzenie do panelu operacyjnego...
Страница 123: ...VTS2000 Series frequency inverter 27 ci stotliwo ci...
Страница 192: ......