VTS2000 Series frequency inverter
- 40 -
method
0
:
starting from the starting frequency
1
:
DC braking first and then starting from the
starting frequency LED tens
:
Power failure or
abnormal restart method
0
:
useless
1
:
starting from the starting frequency
LED hundreds: reserved
LED thousands: reserved
F1.01
Direct
Starting
frequency
Direct starting frequency: refers to the initial
frequency when the inverter starts.
0.0
~
50.0Hz
1.0Hz
○
F1.02
DC braking
current at
starting
Starting DC braking current and time: When the
inverter starts, perform DC braking according to the
set DC braking current before starting, and then start
the acceleration operation after the set DC braking
time before starting. If the DC braking time is set to
0, the DC braking is invalid. The greater the DC
0.0
~
50.0
%
×Motor rated
current
0.0
%
○
Содержание VTS2000 Series
Страница 1: ...VTS2000 Series Frequency Inverter User Manual Controlling and protecting your motor...
Страница 14: ...VTS2000 Series frequency inverter 12 2 Installation and wiring 1 Dimensions...
Страница 16: ...VTS2000 Series frequency inverter 14 2 Basic wiring diagram...
Страница 21: ...VTS2000 Series frequency inverter 19 3 Operation panel introduction...
Страница 96: ......
Страница 111: ...VTS2000 Series frequency inverter 15 2 Instalacja i okablowanie 1 Wymiary...
Страница 113: ...VTS2000 Series frequency inverter 17 2 Podstawowy schemat po cze...
Страница 114: ...VTS2000 Series frequency inverter 18 3 Korespondencja skoczk w...
Страница 121: ...VTS2000 Series frequency inverter 25 3Wprowadzenie do panelu operacyjnego...
Страница 123: ...VTS2000 Series frequency inverter 27 ci stotliwo ci...
Страница 192: ......