![VTS Euroheat DEFENDER 100 EHN Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/vts-euroheat/defender-100-ehn/defender-100-ehn_technical-documentation-manual_1056147016.webp)
16
EN
DEFENDER
100-200 WHN
DEFENDER
100-200 EHN
Parametry
DEFENDER 200 EHN
T
p1
[°C]
5
10
15
20
Flow rate of air at 5000 m
3
/h (speed 3); air velocity at the output: 10,6 m/s; noise level 71 dB(A)*
P
g
[kW]
10,8/13,5**
10,8/13,5**
10,8/13,5**
10,8/13,5**
T
p2
[°C]
11,7/13,4**
16,7/18,4**
21,7/23,4**
26,7/28,4**
Flow rate of air at 3370 m
3
/h (speed 2); air velocity at the output: 7,2 m/s; noise level 62 dB(A)*
P
g
[kW]
10,8/13,5**
10,8/13,5**
10,8/13,5**
10,8/13,5**
T
p2
[°C]
14,2/17,4**
19,2/22,4**
24,2/27,4**
29,2/32,4**
Flow rate of air at 2500 m
3
/h (speed 1); air velocity at the output: 5,5 m/s; noise level 54 dB(A)*
P
g
[kW]
10,8/13,5**
10,8/13,5**
10,8/13,5**
10,8/13,5**
T
p2
[°C]
18,1/20,2**
23,1/25,2**
28,1/30,2**
33,1/35,2**
EN:
* The noise level has been measured within a 3 m distance from the device; reference conditions: semi-open space – wall-mounted device.
EN:
**heating capacity available in Defenders with serial numbers: EHN100 – start from no. 12/00867, EHN150 – start from no. 12/00820, EHN200 – start from no. 12/00544