ShiniCube inverter can realize data reviewing and parameter setting, etc by the monitor
software, the following is a brief introduction to the monitor software, and for more details
please read the instruction manual for the monitor software.
5.3 Introduction to the function of monitor software
5.3.1 Main interface
1) Device list zone: names of all registered devices with the communication state (LIVE or
OFF) are displayed by a module tree, and one of the device can be selected as the current
device by clicking.
2) Accumulated data displaying zone: the total electric quantity, current day power
generated, total power generating time and the current running state of each device in
the device list are displayed by a data table.
3) Current device real-time data zone: the real-time data of the current data including
the I/O power, I/O current, I/O voltage, power factor and efficiency of the current device
are displayed by a data table.
4) Current device current day data curve: the data curve of the current device including the
current day power generated, input power and output power are displayed by curves.
5.3.2 Device management
1) Device registration: a new device can be added into the device list by the user;
2) Device modification: the name of a registered device can be modified by the user;
3) Device deletion: a dismantled device can be deleted from the device list by the user;
5.3.3 Data review
1) History data curve
The history data curve for each device of any day during the storage period can be reviewed,
and the data include the generated electric quantity, I/O power, I/O current and I/O voltage
of the day reviewed.
2) History generated electric quantity
The generated electric quantity during a section of storage period for each device in the
device list can be reviewed, including the total quantity, weekly quantity, monthly
quantity and yearly quantity.
3) The system information of each device in the device list can be reviewed, including the
running state information and fault/ protection information of the device.
Tip
You can download the most updated monitor software and
the corresponding user's manual on our website :
www.victorypower.com
.
Human-machine interaction
ShiniCube1600TL-3300TL User Manual
Victory Power New Energy
VP-UMSC1.0.0EN
32
/47
Содержание ShiniCube 1600TL
Страница 1: ...User Manual Operator 1600TL 2200TL 2800TL 3300TL Installer Maintainer EN PV Grid Tied Inverter...
Страница 2: ......
Страница 57: ......