background image

10

Status Indicator

3. Programming Selectable Options

Note:  You can go into option programming mode without exiting the transmitter learn
mode.  To do so, do not turn the ignition key off or close the doors at the end of the
transmitter programming section and proceed directly to step 2 below.
1.

Enter the transmitter programming mode as indicated above.

2.

Press and release the programming button one time.
The siren will chirp three (3) times to indicate the system is in the option program-
ming mode.

3.

Press the ARM button one time to select option #1.
The siren will chirp one time.
Pressing the disarm button on a programmed transmitter toggles the selected
option’s state on or off.
The status indicator (LED) will display the state of the selected option.
Pressing the ARM button on a programmed transmitter selects the next option.
The siren will emit a number of short chirps corresponding to the selected option
number.
Pressing ARM and DISARM buttons at the same time will reset all options to their
factory preset states.
The siren will chirp and the door locks will cycle once to indicate that the options
have been reset to their factory preset programming.

4.

When all options are set as desired, turn the ignition key off to exit the options
programming mode.

5.

Close all doors to reset the system operation.

Status Indicator
Displays Option Status
(ON or OFF)

Number of Siren Chirps
Indicate Option Number

Button 2
Press to

Turn Option

ON or OFF

Button 1
Press to

Advance to

Next Option

Press BOTH

Buttons (1 and 2)

to Reset all Options

to Factory Settings

Y-10

Y-11

Option Number and Description

Bold Type

 

Indicates Factory Settings

ON

OFF

1 Siren chirps when arming and disarming

YES

NO

2 System arms automatically 60 seconds after last door is closed

YES

NO

3 (1) Siren output enable (2) Horn output enable

(1)

(2)*

4 Doors lock when ignition is turned on

YES

NO

5 Doors unlock when ignition is turned off

YES

NO

6 Double unlock pulse enable

 YES

NO

7 Armed out put enable

YES

NO

8 Door lock / unlock output duration is (1)

1

/

2

 second or (2) 6 seconds

(2)

(1)

* Siren output is the default on the Y-11, Horn is the default on the Y-10

Содержание ELITE911

Страница 1: ...ion Technical Support For Authorized Dealers 800 421 3209 Hours 8 00 a m 7 00 p m EST Monday thru Friday 10 00 a m 2 00 p m EST Saturday Avoid mounting components or routing wires near hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Use grommets when routing wires through metal surfaces Use a voltmeter for testin...

Страница 2: ...RN OUTPUT SHOCK SENSOR WHITE YELLOW GREEN GRAY BLUE BROWN POSITIVE DOOR TRIGGER NEGATIVE DOOR TRIGGER NEGATIVE HOOD TRUNK TRIGGER DISARM BUTTON BROWN SWITCHED POWER BLACK RED STATUS INDICATOR 12 VOLTS FUSED 12V SOURCE ILL ENTRY ARMED OUTPUT Y 11 ONLY System Layout Refer to Wire Color Location Chart for specific wire color location and polarity information Module Identification 7 Tab Connectors Y 1...

Страница 3: ... horn is pressed Diagram 1 Horn Wire Relay Diagram 1 Connect to target wire Positive Negative Connection B 12V Main Feed RED Connect to vehicle battery or to main 12 volt lead at ignition switch harness Circuit Verification Target wire registers voltage at all times C 12V Switched Feed BLUE on 7 Pin Connector Connect to switched 12 volt lead at ignition switch harness Circuit Verification Target w...

Страница 4: ...7 Pin Connector Connect appropriate module wire to vehicle target wire See diagram 2 below Circuit Verification Refer to Vehicle Wire Color and Location Chart for circuit type and location or verify the vehicle wire using the following guideline Positive Systems Target wire registers voltage when any door is opened Negative Systems Target wire registers ground when any door is opened E Starter Int...

Страница 5: ...ation Chart for circuit type and location or verify the vehicle wire using the following guideline Positive Systems Target wire registers voltage when parking lights are on Negative Systems Target wire registers ground when parking lights are on Connections Positive System Negative System Parking Lights Connect to Target wire Add relay dia 4 J Hood Trunk Pin Switch GREENWire on 7 Pin Connector Cir...

Страница 6: ...System 1 Installation GREEN BLACK UNLOCK BLUE BLACK LOCK Diagram 7 Diagram 5 Type 1 Positive 3 Wire Door Lock System GREEN BLACK LOCK BLUE BLACK UNLOCK Type1 Type3 Type2 Other Dia 5 Dia 7 Dia 6 See specifications in Vehicle Wire Color Location Guide or call Technical Support Type4 Dia 8 Door Locks Connections Type5 Dia 9 ...

Страница 7: ...Y Wire on 7 Pin Connector Locate a visible location on the dash with 11 2 clearance Drill 1 4 hole and snap the status indicator in place Connect the status indicator BLACK wire to the module GRAY wire Connect the status indicator RED wire to a fused 12 volt source K Power Door Locks cont To Control Relays Resistors Vehicle Door Lock Switch or Plunger Type 5 Multiplex Door Lock System If door lock...

Страница 8: ...ched to the harness N Override Programming Button The override programming button must be installed for all installations Find a suitable mounting location for the override programming button The selected mounting location should be as difficult as possible for an unautho rized person to find It is recommended that the override button be mounted in different location in each installation Drill a 9...

Страница 9: ...11 or once 1 for the Y 10 Three Remote Transmitters Program one transmitter twice and each remaining transmitter once Y 11 only 1 Open the driver s door and leave open 2 If not already on turn the ignition key to the RUN position 3 Press and hold the programming button In 15 seconds the system will chirp the siren 4 Release the override programming button The system is now in the transmitter learn...

Страница 10: ...e same time will reset all options to their factory preset states The siren will chirp and the door locks will cycle once to indicate that the options have been reset to their factory preset programming 4 When all options are set as desired turn the ignition key off to exit the options programming mode 5 Close all doors to reset the system operation Status Indicator Displays Option Status ON or OF...

Страница 11: ...ors and attempt to start vehicle Vehicle starts Doors lock if Ignition Lock Option is activated Y 11 only Turn ignition off Doors unlock if Ignition Unlock Option is activated Y 11 only Panic Press both buttons Siren sounds parking lights flash for 30 seconds Passive Arming Test only if Passive Option is activated Enter vehicle and close doors Turn Ignition Alarm arms one minute after door is clos...