Packing Press 100 P2
Version: 111300001, M0004459B
Date: 13.12.2013
- 25 / 44 -
9 Fault and error analysis
9.1 General
WARNING AGAINST GENERAL DANGERS
In faults trouble shooting the safety instructions described in the chapter "Basic safety principles"
must be followed without fail!
INFORMATION!
When faults tables on the separate machine/line parts are not otherwise given, you can find
further information on the precise settings in the chapter "Controls and settings work before first
starting up/re-starting of line".
The precise replacement work is described in the chapter "Servicing and Repairs".
9.2 Fault and error analysis
– machine / line components
Fault/Malfunction
Possible cause
Remedy
Unit does not function
Electrical defect
Check the electrical connections, cable links, switches, drives
and fusing (see Section “Checking and setting work before
start-up/re-
starting”)
Piston does not move out
Air in the hydraulic
system
Ventilate the pump with the motor running (see section
“Maintenance and Repairs”)
Leak in the
hydraulic system
Check the hydraulic connections and links (see section
“Checking and setting work before start-up/re-starting”)
Hand wheel on the
bleed valve was not
closed
Close bleed valve
Pressing procedure
cannot be carried out
correctly
Stack not correctly
placed under the
pressure plate
Check the positioning of the collection trough with stack and
correct
Wrong pressed
goods
Remove foreign body and fill with correct pressed goods (see
section “Use for purpose intended”)
Strap tension not
correct (strap slips)
Tighten strap or replace if necessary (see the section
“Servicing and Repairs”)
Collection trough cannot
be moved out
Guide elements
damaged
Replace guide elements
Running rollers
damaged
Replace running rollers