background image

C.  Power Level adjustment 

 
 

End users can Preset the maximum output (charging) current in 10% increments to make the charger suitable for different 

 

Battery capacities &/or loading conditions. 

 

Make sure the Main Switch is OFF before adjust the power level. 

 

Use a small slot type screw driver to select the maximum output current via the Charging Current Selection Switch (5). 

 

The selected max. output current can be viewed on the optional remote panel . 

 
 

Position 0: 40 Amp 

 

Position 9: 36 Amp   

 

Position 8: 32 Amp 

 

Position 7: 28 Amp 

 

Position 6: 24 Amp 

 

Position 5: 20 Amp 

 

Position 4: 16 Amp   

 

Position 3: 12 Amp 

 

Position 2:    8 Amp 

 

Position 1:    4 Amp 

 
 

Recommended Battery Capacity 15AH to 400AH 

 

The extended range of 15 to 400 AH capacity is based on the appropriate charging current selection 10% to 100%. 

 

Some battery type can take higher charge current. 

 

When in doubt check with battery manufacturer for recommended charging current. 

 

D.  Testing the charger with output open circuit (nothing connected to the output terminal) 
 

 

On power up, the charger will do a self check during which all the LED indicators are on and fan in full speed for a few seconds. 

 

Then the Charger On and the Absorption LED are on if charger is checked out OK. 

 

After 5 minute the Float LED will be on and Absorption LED off. 

 

 

 

Remark: 

 

You can connect a load to the output terminal and the charger will provide a constant DC source voltage according to the 

 

‘Battery type’ and available ‘Output power’ (current) settings selected, (as detailed in Sections B3 and C.) 

 

This feature is handy for caravan installer to check the operation of connected powered appliance or connections. 

 
E.  Battery Charger Installation and Connection 

 
 

Observe the warnings & safety precautions before rushing to install and operate the charger. 

 

Check battery condition, fill up cells for wet battery, clean battery poles. 

 

Secure the battery charger in a well ventilated place, make sure the mounting surface is flat and without soft covering material or 

 

loose paper sheet. The air intake is at the bottom and air outlet at the back. Make sure both intake and outlet are not blocked.   

 

Never place charger on top of battery. 

 

Plug in the AC mains and turn on Power Switch. All the indicators on the front panel will lit up, cooling fan spins at full speed 

 

for 10 seconds by means of Self-Testing. 

 

After self-test mode the Charger ON LED and either Bulk LED or Absorption LED will be lit initially (depending on the state of 

 

the battery). 

 

After 5 minutes, if the battery is in a high state of charge, the charger float LED will be lit, otherwise the charger can stay in 

 

either Bulk   

 

Or Absorption mode for longer periods if needed. 

 

Before connecting or disconnecting the charging cable, turn off the Power Switch and unplug AC cord from the mains. 

 

First connect the Battery Chargers Positive (+) terminal to the Battery Positive (+) Post. Then connect the Chargers Negative (–) 

 

terminal to the Battery Negative (–) Post. 

 

For BC-1240P1-AP Model; Connect the Grey 50Amp connector to the Chargers corresponding Connector (9) then connect   

 

The Battery Positive (+) followed by the Battery Negative (-).   

 

Make sure all the connections are 

clean, secured and tight

. Double check for correct polarity. 

 

Double  check  again  for  correct  selection  of  Battery  Selection  Switch  (4)  for  battery  type  (default  at  GEL  P-1)  and  Charging 

 

Current Selection Switch (5) for output current setting (default at 100%) 

 
 

When installed in caravans and similar vehicles, the connection to the supply mains is to be in accordance with national wiring 

 

rules. 

 
 

When charging automotive batteries: 

 

-  The battery terminal not connected to the chassis has to be connected first. The other connection is to be made to the chassis, 

 

 

remote from the battery and fuel line. The battery charger is then to be connected to the supply mains; 

 

-  After charging, disconnect the battery charger from the supply mains. Then remove the chassis connection and then the   

 

 

battery connection. 

 

 

Содержание BC-1240P-1AP

Страница 1: ...f a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as Batteries may give out explosive gas Do not charge batteries in a sealed enclosur...

Страница 2: ...and Calcium Calcium lead acid batteries There are two user programmable charging profiles for the professional users through USB port by personal computer In addition the programmed maintenance charge...

Страница 3: ...Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at low high battery temperature B Using the charger 1 Check the supplied accessories AC c...

Страница 4: ...ry charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loose paper sheet The air intake is at the bottom and air outlet at the back Make sur...

Страница 5: ...s to Float Stage The max Absorption time is also controlled by the time in Bulk charge and battery type selected Stage 3 THE UO PHASE The constant voltage charging Float LED is ON In Float stage the b...

Страница 6: ...ce the Voltage of each cell reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates You can use the Equalization Selection Switch 8 to perform the...

Страница 7: ...duced output power OFF OFF ON At reduced output power as selected Indicates xx Power Set This is not a fault So no specific indication Battery over heat detected by remote temp sensor at 60 C Flashing...

Страница 8: ...elect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable...

Страница 9: ...recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically if Fault Condition is Removed within 20 seconds Otherwise the charger will shutdown until re start the cha...

Страница 10: ...level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mounted on BC char...

Страница 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Страница 12: ...r Level Display current output level 10 Software Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Eq...

Отзывы: